强激光与粒子束, 2005, 17 (7): 1106, 网络出版: 2006-04-28   

HIRFL-CSR实验环电子冷却装置磁场测量

Magnetic field measurement of HIRFL-CSR experimental ring electron cooling device
作者单位
1 中国科学院近代物理研究所,甘肃,兰州,730000
2 中国科学院研究生院,北京,100039
3 俄罗斯科学院,核物理研究所,新西伯利亚,630090
摘要
在HIRFL-CSR实验环电子冷却装置上采用了独立的高精度螺线管串联产生纵向磁场的设计,获得很高的冷却段磁场平行度.使用霍尔片测量磁场的分布,使用磁针测磁方法测量冷却段磁场的磁轴偏角,并根据测量及计算结果对单个线圈磁轴进行微调.测量及调试结果表明,在施加电流为额定电流的一半时,冷却段磁感应强度为0.078 T,剩余磁场小于2×10-4 T,磁场不平行度小于1×10-4,达到了预期的设计目标.
Abstract
The cooling time and cooling efficiency in electron cooling device strongly depend on the transverse temperature of electron beam. In order to reduce this temperature, a new type of cooling section solenoid composed of 68 coils was used in the HIRFL-CSR electron cooling device to produce a high parallelism magnetic field. With the Hall probe, the components of the magnetic field along the ion beam orbit were measured, and using the compass method the magnetic field parallelism in cooling section was measured. According to the measured results, the magnetic axis angle of each coil with respect to the geometric axis was regulated correspondingly. The magnetic field nonparallelism in the cooling section less than 1×10-4 was achieved and a magnetic induction strength of 0.078 T was obtained.

冒立军, 杨晓东, 李杰, 卢旺, 王志学, 燕宏斌, 张玮, 张军辉, 赵红卫, BINP electron cooler group. HIRFL-CSR实验环电子冷却装置磁场测量[J]. 强激光与粒子束, 2005, 17(7): 1106. MAO Li-jun, YANG Xiao-dong, LI Jie, LU Wang, WANG Zhi-xue, YAN Hong-bin, ZHANG Wei, ZHANG Jun-hui, ZHAO Hong-wei, BINP electron cooler group. Magnetic field measurement of HIRFL-CSR experimental ring electron cooling device[J]. High Power Laser and Particle Beams, 2005, 17(7): 1106.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。