强激光与粒子束, 2001, 13 (5): 560, 网络出版: 2006-05-15   

HLS 注入段束流位置探头定标电场的拟合和误差计算

Electric field fit and error calculation of the calibration system of BPMs for HLS injection system
作者单位
中国科学技术大学国家同步辐射实验室,安徽,合肥,230029
摘要
描述了束流位置探测器(BPM)探头定标、定标电场的拟合和误差计算。该定标系统采用了具有调节精度为10μm垂直放置真空管道的天线模拟定标装置和分辨率高达1μm外差式、窄带频域信号处理电子学线路。并推导出针对合肥光源(HLS)定标系统条件下的电场拟合函数及相关的BPMMapping图和误差计算结果,较精确地计算出该高精度定标系统误差。
Abstract
This paper describes the calibration of the newly manufactured BPMs developed for injection system upgrade in NSRL phase II project,as well as the electrical field fitting and error calculation.The antenna calibration system employs an equipment whose precision adjusted to 10μm and with vertical vacuum pipelines,and a signal processor with 1μm of resolution and working in RF of NSRL ring.The fitting error of the electric field is presented.With the calibrating system and processing method which has a system error about ±15μm and the precision of 1μm,we have completed the calibration and quality checking of the developed equipment.Due to the vertically fixed beam pipe and the antenna's movement to simulate beam orbit deviation,as well as the adoption of the RF CW to simulate the beam instead of the traditional 5MHz CW source,the results show fine precision and better reliability.

王筠华, 刘建宏, 刘祖平, 王贵诚. HLS 注入段束流位置探头定标电场的拟合和误差计算[J]. 强激光与粒子束, 2001, 13(5): 560. 王筠华, 刘建宏, 刘祖平, 王贵诚. Electric field fit and error calculation of the calibration system of BPMs for HLS injection system[J]. High Power Laser and Particle Beams, 2001, 13(5): 560.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!