光学学报, 2007, 27 (4): 685, 网络出版: 2007-04-25   

双光头多层数据存储系统同步聚焦误差检测

Synchronizing Focus Error Detection of Dual-Pickup in Multi-Layer Data Storage System
作者单位
中国科学技术大学精密机械与精密仪器系, 合肥 230026
摘要
为实现共焦双光头多层数据存储系统,需要对双光头同步聚焦误差进行检测,以确定聚焦伺服跟踪精度,验证系统的可行性。首先利用几何光学的ABCD变换矩阵计算双光头输出能量与光头间距离的关系,确定其线性工作范围;其次通过输入不同频率的正弦信号驱动音圈电机,获得静止状态、下光头运动状态以及双光头同步运动状态下,四象限探测器的输出信号;最后对输出信号进行频域分析,可计算得到由于双光头参量失配而导致的同步聚焦误差在不同频率下的幅值。实验结果表明,在20 Hz、峰峰值0.5 V正弦信号作用下,同步聚焦误差幅值在1 μm以下,可以满足共焦双光头多层数据存储系统的聚焦伺服跟踪要求。
Abstract
To implement dual-pickup-head multilayer data storage system, it is necessary to measure the synchronizing focus error of the two pickup heads to validate the feasibility of the focus servo method. By using the ABCD transforming matrix method of the geometric optics, we calculate the relationship between the output energy and the space interval of the two pickup heads. After confirming the detection system working in linear area, the coil motors of the two pickup heads were driven by sine signal with different frequency and record the output signals of the photo-detector under different movement states respectively, such as rest, single pickup head movement and dual-pickup-head synchronizing movement. The synchronizing focus error, which is caused by the characteristic parameter mismatch of the two pickup heads, could be obtained through frequency-domain analysis of these output signals. The experimental result shows that the amplitude of synchronizing focus error under 20 Hz is less than 1 μm, which could satisfy the focus servo requirement of the multilayer data storage system well.

沈兆龙, 江兵, 蔡建文, 徐敏, 黄文浩. 双光头多层数据存储系统同步聚焦误差检测[J]. 光学学报, 2007, 27(4): 685. 沈兆龙, 江兵, 蔡建文, 徐敏, 黄文浩. Synchronizing Focus Error Detection of Dual-Pickup in Multi-Layer Data Storage System[J]. Acta Optica Sinica, 2007, 27(4): 685.

本文已被 5 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!