中国激光, 1995, 22 (10): 766, 网络出版: 2007-08-17   

用于分析“神光”装置中大电流放电干扰的放电回路理论模型

Theory Model of the Discharge Circuit for Analysing Great Current Discharge Induced Electromagnetic Interference in "Sheng Guang" Facility
作者单位
中国科学院上海光机所, 上海 201800
摘要
本文报道神光装置放电回路的理论模型;根据理论模型得到的电位计算结果;一种特殊的电位测量电路。电位的计算结果和测量结果十分一致。电路模型和特别的测量电路是改进神光装置放电电路结构和分析并消除电磁干扰的主要办法.
Abstract
In this peper,a circuit theory model for the discharge circuit of "ShenGuang"FaCility,the caculated results for pontentials which are obtained on the basis of the theorymodel,a special pontential measuring circuit and the measured results are reported.Thecaculated results are in good agreement with the measured ones. All reported in this paperare very important,especially,the circuit model and the special measuring circuit are theprincipal means to improve the discharge circuit structure and to analyse and resolve the electromagnetic interference in “Shen Guang” Facility.

黄东海, 徐振华, 远存德, 王剑雄, 韩爱妹. 用于分析“神光”装置中大电流放电干扰的放电回路理论模型[J]. 中国激光, 1995, 22(10): 766. 黄东海, 徐振华, 远存德, 王剑雄, 韩爱妹. Theory Model of the Discharge Circuit for Analysing Great Current Discharge Induced Electromagnetic Interference in "Sheng Guang" Facility[J]. Chinese Journal of Lasers, 1995, 22(10): 766.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote