中国激光, 2009, 36 (1): 19, 网络出版: 2009-02-10   

主动调Q内腔式Nd∶YAG/GdVO4拉曼激光器

Actively Q-Switched Intracavity Nd∶YAG/GdVO4 Raman Laser
作者单位
山东大学信息科学与工程学院, 山东 济南 250100
摘要
研究了激光二极管(LD)端面抽运的主动调Q内腔式Nd∶YAG/GdVO4拉曼激光器的激光特性, 测量了不同抽运功率和脉冲重复频率条件下的平均输出功率和脉冲宽度。当注入的抽运功率为7.44 W, 脉冲重复频率为20 kHz时获得的1174.5 nm拉曼光的最大平均输出功率为1.3 W, 对应的光-光转换效率为17.4%; 当注入抽运功率为6.8 W, 脉冲重复频率为15 kHz时获得的1174.5 nm拉曼光的最大单脉冲能量为74.4 μJ。与Nd∶GdVO4自拉曼激光器进行实验比较和分析, 实验结果表明主动调Q内腔式Nd∶YAG/GdVO4拉曼激光器可以获得比Nd∶GdVO4自拉曼激光器更高的平均输出功率和转换效率。
Abstract
The characteristics of a laser diode (LD) end-pumped actively Q-switched Nd∶YAG/GdVO4 Raman laser are studied. The average output power and pulse width are measured at the different pump power and pulse repetition frequency. At a repetition rate of 20 kHz and an incident pump power of 7.4 W, an average output power of 1.3 W is obtained, and the corresponding optical-to-optical conversion efficiency is 17.4%. The maximum pulse energy of 74.4 μJ is obtained with a repetition rate of 15 kHz and an incident pump power of 6.8 W. Compared with Nd∶GdVO4 self-Raman laser, the actively Q-switched Nd∶YAG/GdVO4 Raman laser has a higher average output power and a higher conversion efficiency at the same experimental conditions.

丛振华, 张行愚, 王青圃, 李述涛, 陈晓寒, 张晓磊. 主动调Q内腔式Nd∶YAG/GdVO4拉曼激光器[J]. 中国激光, 2009, 36(1): 19. Cong Zhenhua, Zhang Xingyu, Wang Qingpu, Li Shutao, Chen Xiaohan, Zhang Xiaolei. Actively Q-Switched Intracavity Nd∶YAG/GdVO4 Raman Laser[J]. Chinese Journal of Lasers, 2009, 36(1): 19.

本文已被 4 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!