中国激光, 2009, 36 (s1): 262, 网络出版: 2009-06-18   

利用CCD近场仪提高高功率激光器三倍频最佳匹配角的调节可靠度

Improve the Adjusting Reliability of Optimum Matching Angular of the Frequency Tripling of High Power Laser by Laser Near Field CCD Diagnostic Device
作者单位
1 中国科学院上海光学精密机械研究所高功率激光物理联合实验室, 上海 201800
2 中国工程物理研究院上海激光等离子体研究所, 上海 201800
摘要
介绍了高功率激光系统的谐波转换系统匹配角调节的离线-在线技术。研究了如何将CCD近场仪应用于离线调节三倍频最佳匹配角, 该方案与光能量判断和肉眼观察光强相比更可靠。实验结果表明三倍频最佳匹配角的调节精度达到20″, 能够满足工程应用的要求。
Abstract
An online-offline program which is applied to find out the optimum matching angular of the frequency tripling of high power laser are intraduced in this paper. Comparing with determining the optimum matching angular by laser energy meter or naked eyes, the laser near field CCD diagnostic device is more reliable. The result shows that the adjusting precision of the optimum matching angular of the frequency tripling can reach 20″, which can meet the requirement of engineering application.

唐顺兴, 季来林, 欧阳小平, 黄奎喜, 朱宝强, 林尊琪. 利用CCD近场仪提高高功率激光器三倍频最佳匹配角的调节可靠度[J]. 中国激光, 2009, 36(s1): 262. Tang Shunxing, Ji Lailin, Ouyang Xiaoping, Huang Kuixi, Zhu Baoqiang, Lin Zunqi. Improve the Adjusting Reliability of Optimum Matching Angular of the Frequency Tripling of High Power Laser by Laser Near Field CCD Diagnostic Device[J]. Chinese Journal of Lasers, 2009, 36(s1): 262.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!