摘要

合肥光源(HLS)电子储存环的束流水平轨道存在缓慢漂移现象,导致轨道水平漂移的主要原因是同步光热效应导致束流位置检测器(BPM)真空室水平移动。为抑制这种现象而研制的合肥光源BPM真空室位移监测系统,利用光栅位移传感器实时监测全环24个BPM真空室的位移,并将数据反馈至HLS控制系统,由控制系统对BPM的轨道测量值进行实时修正,从而提高了慢速轨道反馈系统有效性。

Abstract

The beam horizontal orbit at Hefei light source(HLS) was drifting all along while the storage ring was operating due to the drift of BPM chamber mainly caused by the thermal effect of synchrotron light.To monitor the BPM chamber motion for all BPMs,a BPM chamber motion measurement system is built in real-time to correct the reading of BPMs.The raster gauges are used to measure the displacement,and the displacement data are transmitted by RS485 serial network to an industrial personal computer which processes the data and sends them to HLS control system.The design of BPM chamber motion measurement system is described and the measurement results are given.

Newport宣传-MKS新实验室计划
补充资料

中图分类号:TL506

所属栏目:加速器技术

基金项目:国家自然科学基金项目(10675118,10875117)

收稿日期:2008-12-09

修改稿日期:2009-03-30

网络出版日期:0001-01-01

作者单位    点击查看

李建伟:中国科学技术大学 国家同步辐射实验室,合肥 230029
孙葆根:中国科学技术大学 国家同步辐射实验室,合肥 230029
曹涌:中国科学技术大学 国家同步辐射实验室,合肥 230029
卢平:中国科学技术大学 国家同步辐射实验室,合肥 230029

联系人作者:李建伟(ljianwei@mail.ustc.edu.cn)

备注:李建伟|主要从事束流发射度的测量研究|(1982-),男,内蒙古包头人,硕士。

【1】Kang H S,Lee W W,Park I S,et al.Compensation of BPM chamber motion in PLS orbit feedback system[C]//Proc of PAC2007.2007:290-292.

【2】Tsai Z D,Lee D S,Kuan C K,et al.The effect of improving the temperature variation at the SRRC storage ring[C]//Proc of EPAC 2000.2000:2483-2485.

【3】Tejima M,Arinaga M,Ieiri T,et al.Movement of BPMs due to thermal stress in KEKB[C]//Proc of PAC 2005.2005:3253-3255.

【4】Safranek J,Singh O,Solomon L,et al.Orbit stability improvement at the NSLS X-ray ring[C]//Proc of PAC 1995.1995:2711-2713.

【5】Cao Yong,Sun Baogen,He Duohui,et al.Measurement and analysis of movement of BPM vacuum chamber for HLS[J].Chinese Physics C,2008,32(S1):127-129.

【6】宣科,王琳,王季刚,等.合肥光源束流轨道慢反馈系统[J].中国科学技术大学学报,2007,37(4-5):497-499.(Xuan Ke,Wang Lin,Wang Jigang,et al.The system of slow beam orbit feedback for HLS.Journal of University of Science and Technology of China,2007,37(4-5):497-499)

【7】梁长垠.光栅传感智能位移测量系统[J].传感器技术,2001,20(4):41-43.(Liang Changyin.Raster sensing intelligent shift measurement system.Journal of Transducer Technology,2001,20(4):41-43)

【8】Incremental Length Gauges,RF20X Series[S/OL].Technical description,manual,RIFTEK,http://www.riftek.com/resource/download/rf200_riftek_eng.pdf.

【9】王筠华,孙葆根,李京祎,等.升级的合肥光源闭轨测量系统及其应用[J].强激光与粒子束,2003,15(8):825-829.(Wang Junhua,Sun Baogen,Li Jingyi,et al.Upgraded closed orbit distortion system and its application in Hefei Light Source.High Power Laser and Particle Beams,2003,15(8):825-829)

【10】李为民,刘功发,李川,等.NSRL二期工程中加速器控制系统的改造[J].中国科学技术大学学报,2007,37(4-5):359-363.(Li Weimin,Liu Gongfa,Li Chuan,et al.Upgrade of the accelerator control system in NSRL Phase Ⅱ Project.Journal of University of Science and Technology of China,2007,37(4-5):359-363)

引用该论文

Li Jianwei,Sun Baogen,Cao Yong,Lu Ping. BPM chamber displacement monitor in Hefei light source[J]. High Power Laser and Particle Beams, 2009, 21(7): 1069-1073

李建伟,孙葆根,曹涌,卢平. 合肥光源BPM真空室位移监测系统[J]. 强激光与粒子束, 2009, 21(7): 1069-1073

被引情况

【1】赖龙伟,周伟民,冷用斌,阎映炳,俞路阳,陈之初,袁任贤,陈杰,沈通. 束流轨道与相关环境参数的同步诊断技术. 强激光与粒子束, 2014, 26(1): 15103--1

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF