Chinese Optics Letters, 2010, 8 (5): 443, Published Online: May. 11, 2010  

Gas leakage monitoring with scanned-wavelength direct absorption spectroscopy Download: 1092次

Author Affiliations
1 Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
2 Shengli Engineering Design &
Abstract
A natural gas leakage detector based on scanned-wavelength direct absorption spectroscopy is described. The sensor employs a multi-channel scanned-wavelength direct absorption strategy. It has the potential to simultaneously monitor methane and hydrogen sulfide in open path environment. Traditionally, scanned wavelength direct absorption spectroscopy is the technique choice for natural gas leakage applications because of its simplicity, accuracy, and stability. We perform the gas sensor using direct-absorption wavelength scans with isolated features at 1-kHz repetition rate and the center wavelength is stabilized at the center of the 2 \nu 3 band R(3) line of methane (1.65 \mu m) and the (\nu 1 +\nu 2 +\nu 3) combination band of hydrogen sulfide (1.57 \mu m), respectively. The influence of light intensity fluctuations can be eliminated by using scanned-wavelength direct absorption spectroscopy. Because of the fast wavelength scanning, the sensor has a response time of less than 0.1 s. The sensor can be configured to sense leakages in path-integrated concentrations of, for example, 100-ppm·m hydrogen sulfide and 10-ppm·m methane.

Shuai Zhang, Wenqing Liu, Yujun Zhang, Xiaowen Shu, Dianqiang Yu, Ruifeng Kan, Jinting Dong, Hui Geng, Jianguo Liu. Gas leakage monitoring with scanned-wavelength direct absorption spectroscopy[J]. Chinese Optics Letters, 2010, 8(5): 443.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!