激光技术, 2008, 32 (5): 0449, 网络出版: 2010-06-03  

PML大气探测可靠性验证及探测结果分析

Reliability validation and results analysis of polarization-Mie lidar for atmospheric sounding
作者单位
中国科学院 安徽光学精密机械研究所 大气光学中心,合肥 230031
摘要
介绍了一台新型偏振-米散射激光雷达用于探测大气气溶胶和卷云的消光特性及偏振特性。为了验证激光雷达探测性能可靠性,采用了3种方法:一是对偏振-米散射激光雷达主要性能参量指标的测定;二是偏振-米散射激光雷达与同类激光雷达对比实验;三是偏振-米散射激光雷达与太阳辐射计探测光学厚度对比实验。实验验证了该系统性能稳定,对比实验探测结果基本一致,探测数据可靠。2007-02~2007-05,利用偏振-米散射激光雷达取得了合肥地区卷云退偏振比的观测结果。结果表明,卷云的退偏振比随高度增加而呈现上升趋势,在7km~12km高度范围内,退偏比在0.2~0.5之间,其平均值为0.36±0.06。
Abstract
A new polarization-Mie lidar(PML)used for detecting extinction and polarization characteristic of aerosol and cirrus is described. Three methods for validate reliability of PML are presented. Firstly,the main performance parameters of PML itself are determined. Secondly,the comparison experiments between PML and homogeneous lidar are completed. Finally,aerosol optical depth compared between PML and solar radiometer are finished. The validation results show that PML is steady and reliable. The detected results of depolarization ratio for cirrus over Hefei from February to May in 2007 are also presented and discussed. The cirrus is generally present in the altitude from 7km to 12km,and the depolarization ratio varies from 0.2 to 0.5 with average 0.36±0.06.At the meanwhile,depolarization ratio appears a climbing tendency with the increased height.

王珍珠, 刘厚通, 钟志庆, 迟如利, 刘东, 周军. PML大气探测可靠性验证及探测结果分析[J]. 激光技术, 2008, 32(5): 0449. WANG Zhen-zhu, LIU Hou-tong, ZHONG Zhi-qing, CHI Ru-li, LIU Dong, ZHOU Jun. Reliability validation and results analysis of polarization-Mie lidar for atmospheric sounding[J]. Laser Technology, 2008, 32(5): 0449.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!