强激光与粒子束, 2010, 22 (4): 936, 网络出版: 2010-06-22   

感应电压叠加器驱动阳极杆箍缩二极管型脉冲X射线源

Pulsed X-ray source based on inductive voltage adder and rod pinch diode for radiography
作者单位
西北核技术研究所,西安 710024
摘要
介绍了自行研制的用于闪光照相且基于感应电压叠加器和阳极杆箍缩二极管的X射线源的组成、结构和主要参数。输出电压3 MV的Marx发生器给阻抗7.8 Ω水介质脉冲形成线充电,产生脉宽约70 ns,电压约1 MV的高功率脉冲,经过峰化开关和预脉冲开关后分成3路馈入三级感应电压叠加器感应腔进行电压叠加,感应电压叠加器次级采用真空绝缘传输线,阻抗从40 Ω变成60 Ω,驱动阳极杆箍缩二极管,二极管阴极为石墨,阳极为直径1.2 mm的钨杆,石墨阴极产生的电子束在电流自磁场作用下发生箍缩,轰击阳极,产生小焦斑脉冲X射线。该装置在Marx充电电压为±35 kV时,二极管电压约2.0 MV,二极管电流约为50 kA,半高宽约80 ns;X射线半高宽约为40 ns,剂量约为28 mGy,焦斑约为0.95 mm。利用该X射线源拍摄到了炸药爆炸产生的层裂碎片不同飞行时间的图像。
Abstract
The pulsed X-ray source based on the inductive voltage adder(IVA) and rod pinch diode(RPD) is developed,and its configuration and main parts and output parameters are introduced in detail. The Marx generator with 3.3 MV charges the water pulsed forming lines with 7.8 Ω and produces the high power pulse of 70 ns width with about 1 MV feeding the three IVA cells in parallel through the peaking water switch and the pre-pulse oil switch. The secondary of IVA adopts the vacuum insulation transmission line(VITL) with the impedance from 40 Ω up to 60 Ω,driving the RPD isolated from the output terminal of IVA for 2 m VITL. The diameter of the graphite cathode of RPD is 12 mm,and the diameter of the tungsten anode rod is 1.2 mm. The electron beam from the cathode is pinched to the tip of the anode rod by the electric-magnetic force of the current and emits the pulsed X-ray with small focus spot. When the Marx generator is charged positive/negative 35 kV,typical parameters of RPD are voltage of about 2.0 MV,current of about 50 kA and full width of half magnitude(FWHM) of 80 ns,and the X-ray parameters are FWHM of about 40 ns,dose of 28 mGy and focus spot diameter of 1 mm. The radiographic images of the spalls of Fe and W material produced by explosion are obtained with the developed X-ray source.

孙凤举, 邱爱慈, 杨海亮, 曾江涛, 盖同阳, 梁天学, 尹佳辉, 孙剑锋, 丛培天, 黄建军, 苏兆峰, 高屹, 刘志钢, 姜晓峰, 李静雅, 张众, 宋顾舟, 裴明敬, 牛胜利. 感应电压叠加器驱动阳极杆箍缩二极管型脉冲X射线源[J]. 强激光与粒子束, 2010, 22(4): 936. Sun Fengju, Qiu Aici, Yang Hailiang, Zeng Jiangtao, Gai Tongyang, Liang Tianxue, Yin Jiahui, Sun Jianfeng, Cong Peitian, Huang Jianjun, Su Zhaofeng, Gao Yi, Liu Zhigang, Jiang Xiaofeng, Li Jingya, Zhang Zhong, Song Guzhou, Pei Mingjing, Niu Shengli. Pulsed X-ray source based on inductive voltage adder and rod pinch diode for radiography[J]. High Power Laser and Particle Beams, 2010, 22(4): 936.

本文已被 12 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索