中国激光, 2010, 37 (9): 2340, 网络出版: 2010-08-19   

传导冷却反弹抽运结构的板条激光放大器

Conductively-Cooled and Bounce-Pumped All-Solid-State Double-Stage Slab Laser Amplifier
作者单位
中国科学院 上海光学精密机械研究所 上海市全固态激光器与应用技术重点实验室,上海 201800
摘要
报道了一种传导冷却、双侧面反弹抽运的脉冲运转Nd:YAG两级板条激光放大器。在重复频率条件下,通过实验测试其放大输入输出关系曲线、光束质量、热效应等特性,证明此种类型的放大器具有效率高、光束质量好、结构紧凑、热效应低和功率可定标放大等特性。实验对由单频激光振荡器输出的平均功率1.1 W,脉宽11.3 ns,光束质量因子(M2x ,M2y)为1.2的激光脉冲序列进行放大,当重复频率为125 Hz时,得到平均功率24.1 W,脉宽8.9 ns,光束质量因子M2x=1.53,M2y=1.27的高光束质量放大激光脉冲序列输出。实验结果表明,此种类型的激光放大器在空间探测应用上具有潜力。
Abstract
One kind of conductively-cooled,double-edge-bounce-pumped and pulsed Nd:YAG double-stage slab laser amplifier is reported.When the amplifier operates in pulsed condition,its high efficiency,good beam quality,compactness,weak thermal effects and high scalable gain are proved by the tests of the input-output relationship,beam quality and thermal effects and so on.The pulsed laser generated by a seed injected single-frequency oscillator,whose power is 1.1 W,pulse duration is 11.3 ns and beam quality factor (M2x,M2y) is 1.2,is amplified by the amplifier at the repetition frequency of 125 Hz and high-beam-quality output laser,whose power is 24.1 W,pulse duration is 8.9 ns and beam quality factor M2x is 1.53,M2y is 1.27,is obtained.Experimental results show that this kind of laser amplifier has great potential in the application of space detection.

尹亮, 马秀华, 陆婷婷, 刘珍峰, 王建磊, 朱小磊. 传导冷却反弹抽运结构的板条激光放大器[J]. 中国激光, 2010, 37(9): 2340. Yin Liang, Ma Xiuhua, Lu Tingting, Liu Zhenfeng, Wang Jianlei, Zhu Xiaolei. Conductively-Cooled and Bounce-Pumped All-Solid-State Double-Stage Slab Laser Amplifier[J]. Chinese Journal of Lasers, 2010, 37(9): 2340.

本文已被 6 篇论文引用