摘要

系统提出了一种新的腔式束流位置监测器(BPM), 即跑道型腔式BPM, 并使用微波工作室软件进行了理论研究和模拟计算, 提出了通用设计方法。跑道型腔式BPM的金属腔部分具有跑道形横截面, 引出束流位置偏移激励起的一对偶极模式作为束流位置信号。该方案的偶极模式极化方向固定, 频率分离, 可以解决随机误差产生的横向串扰问题, 其理论位置分辨力可以达到15 nm。

Abstract

A new high brightness injector based on a new photocathode RF electron gun is planned to be installed at Hefei light source. To get high quality electron bunch, precise control of beam position is required. The positional resolution of the beam position monitor(BMP) system designed for RF electron gun should be higher than 10 μm. A new type of cavity BPM with racetrack cavity is designed. The racetrack cavity is a cavity with a racetrack cross section, so that it has a pair of dipole modes with different resonant frequency and fixed polarization direction. The cross-talk problem is then solved. The 3D model of the cavity is simulated in MWS, and the theoretical performance of racetrack BPM and the optimization method are analysed. The theoretical resolution of racetrack cavity BPM can be 15 nm.

中国激光微信矩阵
补充资料

中图分类号:TL506

所属栏目:高功率微波

基金项目:国家自然科学基金项目(10875117);985项目资助(173123200402002);中央高校基本科研业务费专项资金资助课题

收稿日期:2009-11-09

修改稿日期:2009-12-02

网络出版日期:0001-01-01

作者单位    点击查看

罗箐:中国科学技术大学 国家同步辐射实验室, 合肥 230029
孙葆根:中国科学技术大学 国家同步辐射实验室, 合肥 230029
何多慧:中国科学技术大学 国家同步辐射实验室, 合肥 230029
卢平:中国科学技术大学 国家同步辐射实验室, 合肥 230029
王晓辉:中国科学技术大学 国家同步辐射实验室, 合肥 230029
方佳:中国科学技术大学 国家同步辐射实验室, 合肥 230029

联系人作者:罗箐(luoqing@mail.ustc.edu.cn)

备注:罗箐(1984—), 男, 安徽省繁昌人, 博士研究生, 主要从事束流测量研究

【1】张令翊, 庄杰佳, 赵夔, 等. 第四代光源[J]. 强激光与粒子束, 2001, 13(1):51-55.(Zhang Lingyi, Zhuang Jiejia, Zhao Kui, et al. Fourth-generation light sources.High Power Laser and Particle Beams,2001,13(1):51-55)

【2】Sargsyan V. Comparison of stripline and cavity beam position monitors[R].TESLA Report 2004-03, 2004.

【3】Sargsyan V. Cross-talk problem in pill-box cavity[R].TESLA Report 2003-01,2003.

【4】Lill R, Norum W, Morrison L, et al. Design and performance of the LCLS cavity BPM system[C]// Proc of PAC07.2007:4366-4368.

【5】储建华, 赵振堂. C波段腔式束流位置监测器的结构设计[J]. 高能物理与核物理, 2006, 30(4):344-348.(Chu Jianhua, Zhao Zhentang. Design of C-band cavity type beam position monitor.High Energy Physics and Nuclear Physics,2006,30(4):344-348)

【6】Walston S, Chung C, Fitsos P, et al. Design of C-band cavity type beam position monitor[C]//Proc of EPAC06. 2006:1256-1258.

【7】Li Z. S-band cavity BPM for ILC[C/OL].The 2005 ILC Physics and Detector Workshop and 2nd ILC Accelerator Workshop (Snowmass 2005).http://www.hep.ucl.ac.uk/lc/T474/Documentation/ILCAW0901_TALK.PDF.

【8】Xu Wencan, Zhuang Jiejia, Zhao Kui, et al. Cavity BPM design for PKU-FEL injector[J].High Power Laser and Particle Beams,2006,18(9):1564-1568.

【9】张春晖, 孙葆根, 曹涌, 等. Libera数字束流位置处理器在工作点测量中的应用[J]. 强激光与粒子束, 2006,18(6):1003-1006.(Zhang Chunhui, Sun Baogen, Cao Yong, et al. Application of digital beam position processor Libera on tune measurement.High Power Laser and Particle Beams,2006,18(6):1003-1006)

【10】Luo Qing, Sun Baogen, He Duohui. Design of S-band re-entrant cavity BPM[J].Nucl Sci and Tech,2009,20(3):133-139.

引用该论文

Luo Qing,Sun Baogen,He Duohui,Lu Ping,Wang Xiaohui,Fang Jia. Beam position moniter with racetrack cavity[J]. High Power Laser and Particle Beams, 2010, 22(7): 1635-1639

罗箐,孙葆根,何多慧,卢平,王晓辉,方佳. 新型跑道腔式束流位置监测器[J]. 强激光与粒子束, 2010, 22(7): 1635-1639

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF