摘要
为了精确测量自支撑金属薄膜厚度及其厚度分布,提出了基于白光共焦光谱传感器的金属薄膜厚度测量技术。介绍了该技术的测量原理及系统结构,研究了系统的测量不确定度。利用相向对顶安装的白光共焦传感器组、精密位移平台并结合自制的薄膜厚度校准样品,实现了对厚度为10~100 μm的自支撑金属薄膜的厚度及厚度分布的精确测量;通过研究系统的传感器测量不确定度、薄膜厚度校准样品不确定度、上下传感器安装误差及系统重复性测量误差,获得了系统的测量不确定度数据。试验结果表明,该系统的测量不确定度在0.12 μm左右,基本满足惯性约束聚变(ICF)靶参数测量所需的稳定性好、测量精度高、非破坏性测量等要求。
Abstract
To precisely measure the thickness and thickness distribution of a self-supporting metal film, the measurement technology based on a chromatic confocal spectral sensor was established. The measurement principle and system structure were descripted in detail, and the measurement uncertainty was analyzed. The thickness and thickness distribution of the self-supporting metal film with the thickness between 10-100 μm were tested using the sensor group, precise displacement platform and precise calibrated samples. The measurement uncertainty was evaluated based on analysis of sensor accuracy, the uncertainty of calibration sample thickness, the positioning accuracy of two sensors and the system repetition uncertainty. Experimental results indicate that the measurement uncertainty is about 0.12 μm,which satisfies the requirements of Inertial Confinement Fusion(ICF) for target parameter measurement in high stabilization, high precision and non-destruction.

马小军, 高党忠, 杨蒙生, 赵学森, 叶成钢, 唐永建. 应用白光共焦光谱测量金属薄膜厚度[J]. 光学 精密工程, 2011, 19(1): 17. MA Xiao-jun, GAO Dang-zhong, YANG Meng-sheng, ZHAO Xue-sen, YE Cheng-gang, TANG Yong-jian. Measurement of thickness of metal thin film by using chromatic confocal spectral technology[J]. Optics and Precision Engineering, 2011, 19(1): 17.

本文已被 15 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!