摘要
分析了采用阵列法测量高功率微波(HPM)馈源辐射总功率的相关技术环节。仿真计算了某型X带HPM馈源辐射场分布,设计了积分法测量辐射总功率的参数,并对积分总功率与端口注入功率的关系以及积分方法引入的测量误差进行了计算。设计了由8路HPM辐射场功率密度测量系统组成阵列,对馈源辐射场功率密度进行测量,保证功率密度测量结果一致性和重复性。测量结果表明:多路测量系统测量波形相同,单路系统多次重复测量偏差在±0.1 dB内,多路测量系统对同一点辐射场功率密度测量偏差在±0.3 dB内,馈源热测E面方向图与冷测结果基本符合,积分总功率与等效辐射功率测量结果吻合较好。
Abstract
The paper studied the array method for the measurement of X-Band high power microwave(HPM) feed total radiation power. The radiation field of an X-band HPM feed was simulated to determine three key parameters of surface integral method, and the measurement error caused by the integral method was estimated. An array with 8 probes was designed to enhance the power density measurement precision and stability, with each probe carefully tested and calibrated. The measurement result shows that, the pulse waveforms obtained by different probes are almost the same; the power density measurement difference of 3 shots obtained by the same probe is within ±0.1 dB; the power density measurement difference of the 8 different probes is within ±03 dB. Cold and hot tested patterns of the feed agree with each other, and the derived integral total power is consistent with that obtained through equivalent isotropically radiated power measurement within 0.4 dB deviation.

闫军凯, 刘小龙, 叶虎, 杨猛, 晏峰, 崔新红, 周俊. X波段高功率微波馈源辐射总功率阵列法测量技术[J]. 强激光与粒子束, 2011, 23(11): 3149. Yan Junkai, Liu Xiaolong, Ye Hu, Yang Meng, Yan Feng, Cui Xinhong, Zhou Jun. X-band HPM feed total radiation power measurement using array method[J]. High Power Laser and Particle Beams, 2011, 23(11): 3149.

本文已被 5 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!