光学与光电技术, 2011, 9 (6): 50, 网络出版: 2012-01-05   

水下距离选通成像系统参数对成像效果影响的实验研究

Experimental Research on the Influences of Underwater Range-Gated Imaging Systems Parameters on Image Quality
作者单位
1 海军工程大学兵器工程系, 湖北 武汉 430033
2 海军装备部, 北京 100841
摘要
利用自行研制的水下距离选通成像系统在实验水池中对水下靶板进行成像探测,通过改变探测激光能量和像增强器增益,研究了不同系统参数对实际成像探测效果的影响。通过对实验数据的分析,得出了只是提高探测激光能量与ICCD增益不能继续改善探测图像质量,系统参数与探测结果之间存在最优化关系的结论,为水下距离选通成像系统设计提供了有益的结论和指导。
Abstract
The influences of underwater range-gated imaging systems parameters on image quality are investigated experimentally by changing laser power and voltage on the image intensifier. These experiments are carried out in experimental pond and based on underwater range-gated imaging system that designed by us. The experimental data suggests that raise up the laser power and the voltage on image intensifier cannot always improve the image quality. There will be an optimized solution for the underwater range-gated imaging systems design and parameters.

葛卫龙, 张晓晖, 韩宏伟, 华良洪. 水下距离选通成像系统参数对成像效果影响的实验研究[J]. 光学与光电技术, 2011, 9(6): 50. GE Wei-long, ZHANG Xiao-hui, HAN Hong-wei, HUA Liang-hong. Experimental Research on the Influences of Underwater Range-Gated Imaging Systems Parameters on Image Quality[J]. OPTICS & OPTOELECTRONIC TECHNOLOGY, 2011, 9(6): 50.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!