中国激光, 2004, 31 (s1): 384, 网络出版: 2013-01-29
等离子体电极普克尔盒退偏损耗分析
Analyses on Depolarization Losses of Plasma-Electrode Pockels Cell
摘要
通过对普克尔盒由于定向失误以及应力变形在静态及施加半波电压情况下引起的退偏损耗分析和计算,提出了等离子体电极普克尔盒中开关晶体的加工、装校要求以及半波电压平顶起伏指标;在静态条件下,利用研制的等离子体电极普克尔盒对普克尔盒晶体光轴与光束传播方向在不同夹角下的退偏损耗进行了测量.实验结果与计算结果基本相符.
Abstract
By analyses and calculation of the depolarization loss of plasma-electrode Pockels cell (PEPC) caused by the disorientation and strain with or without half wave voltage, the demands of machining and fixing Pockels and the half wave voltage variation are given. The depolarization losses of PEPC under different angle of the switching crystal optical axis and the beam propagating direction are measured The results are accord with the calculating results.
张雄军, 郑奎兴, 吴登生, 董云, 郑建刚, 鲁敬平. 等离子体电极普克尔盒退偏损耗分析[J]. 中国激光, 2004, 31(s1): 384. ZHANG Xiong-jun, ZHENG Kui-xing, WU Deng-sheng, DONG Yun, ZHENG Jian-gang, LU Jing-ping. Analyses on Depolarization Losses of Plasma-Electrode Pockels Cell[J]. Chinese Journal of Lasers, 2004, 31(s1): 384.