强激光与粒子束, 2013, 25 (4): 1059, 网络出版: 2013-03-27  

轨道式多间隙气体开关设计与性能测试

Design of multi-gap rail gas switch and its performance test
作者单位
西北核技术研究所, 强脉冲辐射模拟与效应国家重点实验室, 西安 710024
摘要
针对直线脉冲变压器对低电感、低抖动气体开关的研制需要, 采用垂直布放的平板轨道电极, 组成具有通视结构的水平间隙, 设计了一种多间隙轨道式气体开关。利用Meek击穿判据计算了单间隙自击穿电压, 实测了4个单间隙的自击穿电压及其相对标准偏差, 并根据单间隙自击穿电压, 利用概率分析方法预测了多间隙开关自击穿电压, 计算值与实测结果一致。研究表明: 开关电感最大约109 nH, 自击穿电压相对标准偏差为1.5%, 在60 kV触发电压和48%~74%欠压比下, 开关抖动0.9~2.6 ns。与圆环形电极的多间隙气体开关相比, 多间隙轨道式气体开关自击穿电压更稳定, 也更容易触发。
Abstract
A four-gap, rail gas switch for fast linear transformer drivers (LTDs) has been developed to be of low jitter and low inductance, by using four horizontal gaps constructed by rail electrodes. The electric field of the switch and the hold-off voltage of the single gap of 8 mm were calculated by using electric field numerical simulation and Meek’s Criterion analysis, respectively. A probability analysis method, for predicting self-breakdown voltages of a switch consisting of several gaps in series, is put forward. The calculated self-breakdown voltages were in agreement with the experimental results. The switch inductance of no more than 109 nH provides the LTD brick a measured inductance of 290 nH. The relative standard deviation of self-breakdown voltage is about 1.5%. Under a 60 kV forward voltage pulse, the switch with 48%-74% voltage ratio has a close jitter of 0.9-2.6 ns. Compared with a previously developed switch with toroidal electrodes, the rail gas switch has a lower trigger voltage and self-breakdown stability while operating at the same voltage ratio.

丛培天, 吴撼宇, 孙铁平, 李岩, 雷天时, 曾正中, 邱爱慈. 轨道式多间隙气体开关设计与性能测试[J]. 强激光与粒子束, 2013, 25(4): 1059. Cong Peitian, Wu Hanyu, Sun Tieping, Li Yan, Lei Tianshi, Zeng Zhengzhong, Qiu Aici. Design of multi-gap rail gas switch and its performance test[J]. High Power Laser and Particle Beams, 2013, 25(4): 1059.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!