红外技术, 2014, 36 (7): 556, 网络出版: 2014-12-08  

红外凝视成像系统中的微扫描器控制

Micro-scanner Control In Staring Infrared Imaging Systems
作者单位
昆明物理研究所, 云南 昆明 650223
摘要
基于压电陶瓷驱动器, 选用 2×2微扫描模式, 降低了系统控制难度。分析了影响微扫描器控制的几个因素, 设计了一款以单片机为核心的控制电路, 解决了微扫描器位移与同步的控制问题, 并以此构建了一款基于国内某制冷型探测器的反射式微扫描热像仪, 通过实验验证了采用 2×2微扫描模式能够有效提升热像系统的空间分辨力。
Abstract
Based on piezoelectric ceramic actuators, 2×2 micro-scan mode was chosen to reduce the difficulty of system controlling. Factors affecting the micro-scanner controlling were analyzed. A microcontroller as the core of the circuit was designed to solve the problem of displacement and synchronization in micro-scanner controlling. A reflecting micro scanning thermal imager was built using cooled detectors. Verified by experiments, the 2×2 micro-scan mode can effectively improve the spatial resolution of thermal imaging systems.

杨登全, 姜炜波, 黄江平, 姬玉龙, 赵薇薇, 王羽, 程有度. 红外凝视成像系统中的微扫描器控制[J]. 红外技术, 2014, 36(7): 556. YANG Deng-quan, JIANG Wei-bo, HUANG Jiang-ping, JI Yu-long, ZHAO Wei-wei, WANG Yu, CHENG You-du. Micro-scanner Control In Staring Infrared Imaging Systems[J]. Infrared Technology, 2014, 36(7): 556.