大气与环境光学学报, 2015, 10 (1): 87, 网络出版: 2015-01-27  

基于非制冷红外焦平面探测器的工业测温系统

Industrial Temperature Measurement System Based on Uncooled IRFPA Detector
作者单位
1 安徽邮电职业技术学院计算机系, 安徽 合肥 230031
2 安徽大学物理与材料科学学院, 安徽 合肥 230031
摘要
传统的非接触性测温系统主要采用红外CCD,其工作波长大多为0.4~1.1 μm,受到截止波长的 影响,红外CCD在工业中低温测量误差过大。非制冷焦平面红外热像仪(uncooled IRFPA camera)的工作波 长一般在8~14 μm之间,常温环境下测温可精确到0.01℃。UL01011型非制冷微测辐射热计是非 制冷焦平面热像仪中最常使用的核心光电探测器,以此作为实验用光电探测器件,构建了非接触性工业测 温系统,从实验结果可以看出,该方法在实际应用中获得了较好的效果。
Abstract
In the aspect of infrared detector, the operating wavelength of the traditional infrared CCD is 0.4~1.1 μm. Affected by the cut-off wavelength, the error of infrared CCD is very large in industrial low temperature measurement. The operating wavelength of uncooled infrared focal plane array (IRFPA) camera is generally between 8~14 μm, of which temperature measurement accuracy can reach to 0.01℃ under the optimum working environment. The UL01011, most commonly used as the core photo detector in the uncooled focal plane uncooled micro-bolometer array infrared camera, was used as the experimental photoelectric detector. Experimental results showed that this method can achieve better results in practice.

陈明武, 吴海滨. 基于非制冷红外焦平面探测器的工业测温系统[J]. 大气与环境光学学报, 2015, 10(1): 87. CHEN Mingwu, WU Haibin. Industrial Temperature Measurement System Based on Uncooled IRFPA Detector[J]. Journal of Atmospheric and Environmental Optics, 2015, 10(1): 87.