激光技术, 2015, 39 (1): 140, 网络出版: 2015-02-15   

三坐标激光测量技术规范中参量确定的方法

Parameters determination method in three-coordinate laser measurement technical specification
作者单位
上海大学 机电工程与自动化学院, 上海 200072
摘要
为了确定三坐标激光测量的最佳参量组合, 获得较好的测量效果, 采用正交实验法进行了理论分析和实验验证。在选取实验中设置的第10档最快速率、频率选取为30Hz、景深水平选取为最佳景深、角度垂直于被测工件表面的参量组合下, 测量效果最佳。结果表明, 该研究中参量选择从定性跨越至定量, 可有效改善三坐标激光测量过程中参量选取难的问题。
Abstract
In order to determine the optimal parameters for three-coordinate laser measurement, and get better measurement effect, theoretical analysis and experimental verification were conducted based on the orthogonal test. The best performance could be achieved under the conditions of speed at the tenth fastest set, frequency at 30Hz, optimum depth-of-field and angle perpendicular to the surface of the workpiece. The results show that it becomes easy to choose parameters in the three-coordinate laser measurement, after qualitative analysis and quantitative analysis.

柳静, 李明, 詹高伟, 肖武华, 韦庆玥. 三坐标激光测量技术规范中参量确定的方法[J]. 激光技术, 2015, 39(1): 140. LIU Jing, LI Ming, ZHAN Gaowei, XIAO Wuhua, WEI Qingyue. Parameters determination method in three-coordinate laser measurement technical specification[J]. Laser Technology, 2015, 39(1): 140.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote