X射线CT技术体积重构法表征异形泡沫金密度

Density characterization of gold foam sample with abnormal surface using X-ray CT technology

  • 摘要
  • 论文信息
  • 参考文献
  • 被引情况
  • PDF全文
分享:

摘要

采用X射线CT(XCT)技术进行体积重构的研究方法, 解决了异形泡沫金密度表征中体积难以精确测量的问题, 密度表征结果为978.68 mg/cm3。同时, 为了研究该方法的有效性与不确定度, 开展了XCT体积重构法与排水法对具有不规则外形橡皮泥样品的密度表征对比实验, 结果表明两者之间的相对误差小于1%。

Abstract

Gold foam is one of the most important materials used in ICF experimental research, while it is hard to precisely measure the volume of the gold foam in its density characterization. Here we reported one method of volume reconstruction by using X ray CT technology. By using this method, the density of our prepared gold foam with abnormal surface is determined to be 978.68 mg/cm-3. To validate the accuracy of this method, comparison experiments between this method and a specific gravity bottle method have been performed by using plasticine samples. The results show that the relative error value is less than 1%.

中国激光微信矩阵
补充资料

中图分类号:O434.1;O616

DOI:10.11884/hplpb201527.032023

所属栏目:ICF实验

基金项目:国家高技术发展计划项目

收稿日期:2014-09-25

修改稿日期:2015-01-07

网络出版日期:--

作者单位    点击查看

黎维华:中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
王远:中国工程物理研究院 应用电子学研究所, 四川 绵阳 621900国家X射线数字化成像仪器中心, 四川 绵阳 621900
谭秀兰:中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
杨波:中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
李敬:中国工程物理研究院 应用电子学研究所, 四川 绵阳 621900国家X射线数字化成像仪器中心, 四川 绵阳 621900
陈云斌:中国工程物理研究院 应用电子学研究所, 四川 绵阳 621900国家X射线数字化成像仪器中心, 四川 绵阳 621900
张成鑫:中国工程物理研究院 应用电子学研究所, 四川 绵阳 621900国家X射线数字化成像仪器中心, 四川 绵阳 621900
刘清华:中国工程物理研究院 应用电子学研究所, 四川 绵阳 621900国家X射线数字化成像仪器中心, 四川 绵阳 621900

联系人作者:黎维华(494161736@qq.com)

备注:黎维华(1974-), 男, 副研究员, 主要从事THz技术研究;

【1】谭秀兰,牛高,李恺,等.模板沉积-去合金化法制备块体泡沫金[J].稀有金属材料与工程, 2013, 42(1): 162-165.(Tan Xiulan, Niu Gao, Li Kai, et al. Preparation of monolithic foamed gold by a template deposit-dealloying method. Rare Metal Materials and Engineering, 2013, 42(1): 162-165)

【2】谭秀兰,牛高,李恺,等.种子-生长法制备块体泡沫金[J].稀有金属材料与工程, 2012, 42(1): 169-172.(Tan Xiulan, Niu Gao, Li Kai, et al. Preparation of monolithic foamed gold by seed-mediated growth. Rare Metal Materials and Engineering, 2012, 42(1): 169- 172)

【3】邓任远.光学三角法在大面积体积测量中的应用[J].光学 精密工程, 1994, 2(4): 121-130.(Deng Renyuan. Application of opticaI triangulation imaging to measure the volume from a large area object. Optics and Precision Engineering, 1994, 2(4): 121-130)

【4】李正群,计欣华.非接触体积测量实验系统[J].物理实验, 2005, 25(3): 39-41.(Li Zhengqun, Ji Xinhua. Non-contract volume measuring system. Physics Experimentation, 2005, 25(3): 39-41)

【5】杨波,周秀文,何伟,等.Z箍缩动态黑腔负载装配用胶粘剂[J].强激光与粒子束, 2013, 25(2): 389-393.(Yang Bo, Zhou Xiuwen, He Wei, et al. Adhesives for assemblage of Z-pinch dynamic hohlraum load. High Power Laser and Particle Beams, 2013, 25(2): 389-393)

【6】杨云昊.硬X射线显微和纳米CT技术在细胞成像中的应用[D].合肥: 中国科学技术大学, 2010.(Yang Yunhao. Study on the applications of hard X-ray microscopy and nano-CT in cellular imaging. Hefei: University of Science and Technology of China, 2010)

【7】肖智强,管永红.高能闪光X光透视成像测量球对称物体密度的方法[J].无损检测, 2010, 32(11): 836-837.(Xiao Zhiqiang, Guan Yonghong. Method for measuring the density of spherical objects by high-energy flash X-ray radiograph. Nondestructive Detection Technology, 2010, 32(11): 836-837)

【8】杨雪海,张伟斌,戴斌,等.含能材料密度的XCT自参照测试[J].无损检测, 2010, 32(6): 431-433.(Yang Xuehai, Zhang Weibin, Dai Bin, et al. Self-comparison based X-ray computed tomography for measuring narrow densities of energy material. Nondestructive Detection Technology, 2010, 32(6): 431-433)

【9】王远.高能工业CT数据采集系统及图像重建研究[D].绵阳: 中国工程物理研究院, 2008.(Wang Yuan. The data acquisition system and image reconstruction for high energy industrial X-ray CT. Mianyang: China Academy of Engineering Physics, 2008)

引用该论文

Li Weihua,Wang Yuan,Tan Xiulan,Yang Bo,Li Jing,Chen Yunbin,Zhang Chengxin,Liu Qinghua. Density characterization of gold foam sample with abnormal surface using X-ray CT technology[J]. High Power Laser and Particle Beams, 2015, 27(3): 032023

黎维华,王远,谭秀兰,杨波,李敬,陈云斌,张成鑫,刘清华. X射线CT技术体积重构法表征异形泡沫金密度[J]. 强激光与粒子束, 2015, 27(3): 032023

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF