光散射学报, 2015, 27 (1): 54, 网络出版: 2015-09-08  

动态光散射及电子显微镜纳米颗粒测量方法的比较研究

Comparison Study on DLS and SEM Methods of Measuring Nanoparticle Size
作者单位
1 浙江省计量科学研究院, 杭州 310013
2 中国计量学院光学与电子科技学院, 杭州 310018
摘要
本文以聚苯乙烯纳米颗粒作为测量对象,分别采用最为常见的扫描电子显微镜法(SEM)和动态光散射法(DLS)测量其粒径.结果表明:电子显微镜法可观察颗粒形貌及结构,但测量误差偏大;动态光散射法可精确测量颗粒粒径及其分布状态.分析讨论了这两种测量方法的优缺点,对纳米颗粒测量具有重要的指导作用.
Abstract
In this paper,we measured the size of the polystyrene nanoparticle by using the most common methods:scanning electron microscopy (SEM)and dynamic light scattering (DLS).Experimental results showed the particle morphology and structure could be observed with SEM method,but the corresponding measuring error was relatively large;while the DLS method could accurately measure the nanoparticle size and its distribution.The advantages and disadvantages of the two measurement methods were discussed,which has an important directing role of nanoparticle measurement.

陈哲敏, 胡朋兵, 孟庆强. 动态光散射及电子显微镜纳米颗粒测量方法的比较研究[J]. 光散射学报, 2015, 27(1): 54. CHEN Zhe-min, HU Peng-bing, MENG Qing-qiang. Comparison Study on DLS and SEM Methods of Measuring Nanoparticle Size[J]. The Journal of Light Scattering, 2015, 27(1): 54.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!