摘要
制冷型InSb红外焦平面探测器工作时需降温至低温(80 K),器件在整个生命周期会经受从常温(300 K)到低温(80 K)的上千次高低温循环。针对该型探测器开展了高低温循环特性试验,测试和分析了上千次高低温循环过程中器件光电性能、杜瓦热负载和J-T制冷器特性的变化。试验结果表明,探测器可以经受至少2 000次高低温循环,并且探测率变化的幅度≤5.5%、响应率变化的幅度≤4.8%、盲元数未发生增加。研究结果为器件的工艺研发和改进提供了参考。
Abstract
The cooled InSb infrared focal plane array(IRFPA) detectors should work in the temperature as low as 80 K. As a result, detectors are commonly subjected to thousands of thermal cycle from 80 K to room temperature(300 K) in the entire life cycle. Thermal cycle characteristic of the InSb IRFPA detector was studied. The FPA photoelectric parameter, Dewar heat load and J-T cooling characteristics were analyzed. The results indicated that the maximal fluctuation of the detectivity was 5.5%, the maximal fluctuation of the responsivity was 4.8%, and the number of dead pixels did not increase. The experimental results exhibited that the detectors could undergo at least 2 000 thermal cycles, which provides reference for the research and improvement of detector fabrication.

王洋, 鲁星, 孟超, 刘俊明, 邝永变, 孟庆端, 朱旭波, 司俊杰. InSb焦平面探测器高低温循环特性研究[J]. 红外与激光工程, 2015, 44(12): 3701. Wang Yang, Lu Xing, Meng Chao, Liu Junming, Kuang Yongbian, Meng Qingduan, Zhu Xubo, Si Junjie. Thermal cycle characteristic of InSb focal plane array detector[J]. Infrared and Laser Engineering, 2015, 44(12): 3701.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!