首页 > 论文 > 强激光与粒子束 > 28卷 > 11期(pp:115103--1)

HLS-Ⅱ储存环工作点测量系统的开发

Development of tune measurement system for HLS-Ⅱ storage ring

  • 摘要
  • 论文信息
  • 参考文献
  • 被引情况
  • PDF全文
分享:

摘要

介绍了在合肥光源重大维修改造工程期间, 开发的一套基于扫频激励法的工作点测量系统。测量系统硬件包括基于条带BPM的信号拾取电极、前端信号调理模块、一台带跟踪输出的信号分析仪N9000AEP、功率放大器以及用于激励束流的条带激励器。系统控制软件采用EPICS开发, 基于EPICS Stream Device设计的输入输出控制器(soft IOC)运行在服务器虚拟机中, 通过VXI11协议进行通信实现对信号分析仪的控制和数据获取; 用户操作界面采用EPICS平台下的EDM开发, 通过Channel Access与IOC通信。在HLS-II储存环上对工作点测量系统进行了在线的调试。调试结果说明, 在扫频范围为2.1 MHz到4.1 MHz时, 工作点测量系统的统计分辨率在水平方向上好于0.000 3, 在垂直方向上好于0.000 2。

Abstract

In the HLS-Ⅱstorage ring, a swept-frequency excitation(SFE) based tune measurement system has been developed and running well. This paper presents the construction and commissioning of the SFE-based tune measurement system. The system hardware includes spectrum analyzer with tracking, excitation module, strip-line kicker, signal processing module and beam position monitor(BPM) as signal pickup. The control software of the tune measurement system is developed using EPICS software. The control software consists of three parts: input/output controller, operation personal interface and channel access. The on-line test of the system is performed to investigate the system statistical resolutions in the two transverse directions. Test results reveal that the statistical resolutions are better than 0.0003/0.000 2 in the swept range from 2.1 MHz to 4.1 MHz.

中国激光微信矩阵
补充资料

中图分类号:TN242

DOI:10.11884/hplpb201628.160057

所属栏目:加速器技术

基金项目:supported by National Natural Science Foundation of China (11105141, 11175173)

收稿日期:2016-02-22

修改稿日期:2016-04-06

网络出版日期:--

作者单位    点击查看

郑佳俊:中国科学技术大学 国家同步辐射实验室, 合肥 230029
杨永良:中国科学技术大学 国家同步辐射实验室, 合肥 230029
程超才:中国科学技术大学 国家同步辐射实验室, 合肥 230029
孙葆根:中国科学技术大学 国家同步辐射实验室, 合肥 230029
吴芳芳:中国科学技术大学 国家同步辐射实验室, 合肥 230029
段青明:中国科学技术大学 国家同步辐射实验室, 合肥 230029

联系人作者:Zheng Jiajun(zhengjj@mail.ustc.edu.cn)

备注:Zheng Jiajun(1989-), male, master candidate, engaged in accelerator physics and diagnostics;

【1】Bai Zhenghe, Wang Lin, Jia Qika, et al. Lattice study for the HLS-Ⅱ storage ring[J]. Chinese Physics C, 2013, 37: 047004.

【2】Wiedemann H.Particle accelerator physics [M]. 3rd ed. Heidelberg: Springer, 2007: 252-255.

【3】Minty M G, Zimmermann F. Measurement and control of charged particle beams[M].Heidelberg: Springer, 2013: 17-27.

【4】Borer J, Guignard G, Hofmann A, et al. Information from beam response to longitudinal and transverse excitation[J].IEEE Trans Nuclear Science, 1979, 26(3): 3405-3408.

【5】Kraimer M R, Anderson J B, Johnson A N, et al. EPICS application developer''s guide[Z]. 2015.

【6】Agilent Technologies. Product fact sheet[EB/OL]. http: //literature.cdn.keysight.com/litweb/pdf/5990-6912EN.pdf.

【7】Li Wubin, Zhou Zeran, Sun Baogen, et al. Design and simulation of stripline kicker for HLS IItransverse feedback system[J]. Atomic Energy Science and Technology, 2013, 47(7): 1250-1255.

【8】Wu Fangfang, Zhou Zeran, Sun Baogen, et al. Offline calibration of stripline beam position monitor for HLS Ⅱ[J].High Power Laser and Particle Beams, 2013, 25(11): 2971-2975.

【9】Zhang Demin, Jin Xiao, Li Ming, et al. Application of EPICS to accelerator control system[J]. High Power Laser and Particle Beams, 2008, 20(4): 597-600.

【10】Sekoranja M, Hunt S, Luedeke A. Visual DCT-visual EPICS database configuration tool[C]//8th International Conference on Accelerator & Large Experimental Physics Control Systems. 2001: 540-542.

【11】Qiao Xianjie, Li Gang. Research of StreamDevice applications based on EPICS[J]. Nuclear Electronics & Detection Technology, 2011, 31(10): 1073-1076.

【12】Evans K. MEDM reference manual[Z]. 2014.

引用该论文

Zheng Jiajun,Yang Yongliang,Cheng Chaocai,Sun Baogen,Wu Fangfang,Duan Qingming. Development of tune measurement system for HLS-Ⅱ storage ring[J]. High Power Laser and Particle Beams, 2016, 28(11): 115103

郑佳俊,杨永良,程超才,孙葆根,吴芳芳,段青明. HLS-Ⅱ储存环工作点测量系统的开发[J]. 强激光与粒子束, 2016, 28(11): 115103

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF