Chinese Optics Letters, 2017, 15 (7): 070601, Published Online: Jul. 20, 2018  

Simple capillary-based extrinsic Fabry–Perot interferometer for strain sensing Download: 1062次

Author Affiliations
Laboratory of Specialty Fiber Optics and Optical Access Networks, School of Communication and Information Engineering, Shanghai University, Shanghai 200072, China
Abstract
A simple capillary-based extrinsic Fabry–Perot structure is presented and fabricated, using the manual welding method with the strain sensing characteristics investigated in detail. Strain sensitivities of 4.2, 2.8, and 2.4 pm/με are obtained experimentally with the interferometer length around 50 μm and the inner diameter of 75, 50, and 25 μm, respectively. The underlying physics of the strain sensitivity of this device is negatively correlated with the interferometer length and positively correlated with the capillary inner diameter, which provides two simple parameters to tailor the strain sensitivity.

Xiaobei Zhang, Haiyang Shao, Haiyang Pan, Yong Yang, Huawen Bai, Fufei Pang, Tingyun Wang. Simple capillary-based extrinsic Fabry–Perot interferometer for strain sensing[J]. Chinese Optics Letters, 2017, 15(7): 070601.

引用该论文: TXT   |   EndNote

相关论文