提出一种基于正交调制的激光测距系统, 该方案与传统的二次混频方法相比, 提高了相位测量精度并简化了系统的硬件设计, 针对距离测量过程中的距离模糊问题, 提出了一种基于超定方程组的距离解模糊算法, 避免了对最优解的搜索, 最后使用2台K60激光测距仪和3台基于本方案的测距仪在精度为018 mm的国家标准基线上进行对比试验, 结果显示, 测距时间少于18 s, 平均测量误差在2 mm以内, 在60 m的量程内测距标准差在1 mm以内, 验证了该方案相比较传统的方法具有更高的测量精度和速度。
Abstract
We propose a laser rangefinder system based on the quadrature modem to achieve amplitude modulation, the method improves the accuracy of the phase measuring and simplifies the hardware design compared to the system with the secondary mixing methods, and to solve the range ambiguity caused by the measuring process, the ranging ambiguity resolving algorithm based on the over-determined equation is proposed, which avoids the searching of the optimal solution, finally the two K60 laser rangefinders and three proposed rangefinders were experimented on the national standard baseline with the precision of 018 mm. the measuring time of the proposed system is less than 18 s, the average measuring error of those three prototypes is less than 2 mm, and the standard deviation is less than 1 mm within the measuring range 0~60 m. The experimental results show that the proposed design system of the rangefinder has higher measurement accuracy and speed in comparison with the traditional ones, which indicates the high reliability of the proposed design system.

赵文成, 许贤泽, 刘盼盼, 程文强, 徐逢秋. 基于正交调制的激光测距系统和解模糊方法[J]. 光谱学与光谱分析, 2017, 37(2): 659. ZHAO Wen-cheng, XU Xian-ze, LIU Pan-pan, CHENG Wen-qiang, XU Feng-qiu. [J]. Spectroscopy and Spectral Analysis, 2017, 37(2): 659.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!