光电子快报(英文版), 2015, 11 (2): 145, Published Online: Oct. 12, 2017   

A non-contact real-time measurement of lamp dimension based on machine vision

Author Affiliations
1 Key Laboratory of Advanced Electrical Engineering and Energy Technology, Tianjin Polytechnic University, Tianjin 300387, China
2 School of Electrical, Computer and Telecommunications Engineering, University of Wollongong, Keiraville 2500, Australia
3 Baoding Life Automotive Lighting Group Company Limited, Baoding 071000, China
Abstract
In order to realize the online measurement of lamp dimension, the bulb image dimension measurement based on vision (BIDMV) is proposed. The image of lamp is obtained by camera. After image processing, such as Otsu algorithm, median filter, ellipse fitting and envelope rectangle fitting, the dimension of lamp can be calculated. Based on this method, a non-contact real-time measurement system of the lamp’s dimension is developed. The precision of the proposed method is 0.07 mm, and it can satisfy the tolerance of the National Standard GB15766.1-2008. The experiment results show that the proposed method has a faster measuring speed and a higher precision compared with other measurement methods.

SONG Li-mei, WANG Peng-qiang, CHANG Yu-lan, LI Xiao-jie, XI Jiang-tao, GUO Qing-hua, LI Bing-nan. A non-contact real-time measurement of lamp dimension based on machine vision[J]. 光电子快报(英文版), 2015, 11(2): 145.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!