光学仪器, 2018, 40 (3): 8, 网络出版: 2018-08-04   

辐射光谱测温法测量误差实验研究

Experimental research on measurement error of radiation spectroscopy thermometry
作者单位
1 上海理工大学 上海市动力工程多相流动与传热重点实验室, 上海 200093
2 上海航天动力技术研究所, 上海 201109
摘要
针对辐射光谱测温法测量误差问题,利用黑体炉搭建了标准辐射测温实验平台,选用200~1 100 nm波段光谱仪对标准高温源进行辐射光谱测量。讨论了高温源辐射光谱特征,并基于辐射光谱测温法获得了温度测量值,该值与标准参考值的相对偏差小于4%,同时分析了测量重复性引起的标准不确定度分量,为辐射测温法应用提供参考。
Abstract
In order to obtain the measurement error of radiation spectroscopy thermometry,the standard experimental platform was established by black body furnace.The spectrometer with 200~1 100 nm was selected to measure the radiation spectrums of standard high-temperature source.The spectral characteristics were discussed in detail.And the temperature results were determined based on spectroscopy thermometry.Compared with the standard value,the relative deviations are less than 4%.The uncertainty components of the repeated measurements were analyzed.It provides important reference for applications of radiation spectroscopy thermometry.

ALLIOT Aymeric, 徐秋丽, 杨敬贤, 郭浩然, 杨斌, 蔡小舒. 辐射光谱测温法测量误差实验研究[J]. 光学仪器, 2018, 40(3): 8. ALLIOT Aymeric, XU Qiuli, YANG Jingxian, GUO Haoran, YANG Bin, CAI Xiaoshu. Experimental research on measurement error of radiation spectroscopy thermometry[J]. Optical Instruments, 2018, 40(3): 8.

本文已被 2 篇论文引用