大气与环境光学学报, 2019, 14 (4): 296, 网络出版: 2019-08-13   

双通道自校准辐射计与辐亮度标准探测器的比对实验研究

Comparison Experiment of Two-Channel Self-Calibration Radiometer and Radiance Standard Detector
作者单位
1 中国科学院安徽光学精密机械研究所中国科学院通用光学定标与表征技术重点实验室 安徽 合肥 230031
2 中国科学技术大学, 安徽 合肥 230026
摘要
基于自发参量下转换的高精度自校准辐射基准源是目前卫 星遥感定标的研究热点。介绍了双通道自校准辐射计的工作原理并搭建了实验装置,展开了与传统 辐亮度标准探测器的比对实验验证。采用736.9 nm激光导入积分球的单色均匀辐亮度光源,将双通道 自校准辐射计和辐亮度标准探测器分别对积分球出口辐亮度进行探测,测得绝对辐亮度分 别为4.69×10-9 W/(sr·mm2)和5.19×10-9 W/(sr·mm2), 二者之间的相对偏差为9.63%,验证了研制的双通道自校准辐射计的原理可行性。
Abstract
High-precision self-calibration radiation reference source based on spontaneous parametric down-conversion is the research hotspot of satellite remote sensing calibration. The principle of two-channel self-calibration radiometer was introduced, and a set of experimental device was established. The experimental verification was carried out by comparing with traditional radiometric standard detector. Monochromatic uniform radiance light source with 736.9 nm laser was used by integrating sphere, then the radiance at the outlet of integrating sphere was detected by two-channel self-calibration radiometer and radiance standard detector respectively. The measured absolute radiances results were 4.69×10-9 W/(sr·mm2) and 5.19×10-9 W/(sr·mm2), and the relative deviation was 9.63%. The feasibility of the principle of two-channel self-calibration radiometer was verified.

白米粒, 李健军, 高冬阳, 胡友勃, 谢臣瑜, 闫静, 郑小兵. 双通道自校准辐射计与辐亮度标准探测器的比对实验研究[J]. 大气与环境光学学报, 2019, 14(4): 296. BAI Mili, LI Jianjun, GAO Dongyang, HU Youbo, XIE Chenyu, YAN Jing, ZHENG Xiaobing. Comparison Experiment of Two-Channel Self-Calibration Radiometer and Radiance Standard Detector[J]. Journal of Atmospheric and Environmental Optics, 2019, 14(4): 296.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网