激光与光电子学进展, 2020, 57 (5): 051701, 网络出版: 2020-03-05   

糖尿病患者视网膜血氧饱和度及血管直径变化的无创测量 下载: 1379次

Noninvasive Measurement of Retinal Oxygen Saturation and Vessel Diameter Changes in Diabetes Mellitus Patients
作者单位
1 北京大学工学院生物医学工程系, 北京 100871
2 北京大学第一医院眼科, 北京 100034
3 北京大学深圳研究生院生物医学工程研究所, 广东 深圳 518055
4 深圳湾实验室, 广东 深圳 518052
摘要
利用视网膜功能测量仪对眼底进行结构成像来直接观察体内丰富的循环系统,并对视网膜的血氧饱和度及血管直径进行无创、定量的功能性成像测量。对糖尿病患者和健康人群进行视网膜功能成像并作定量比较分析,结果表明,在糖尿病患者中,视网膜动脉血氧饱和度相比健康人群有显著性提高,视网膜动静脉血氧饱和度差值有显著性增大,视网膜黄斑中心凹无灌注区面积也有显著增大。此外,在糖尿病患者和健康人群中,视网膜动静脉的直径均存在差异,且静脉直径总大于动脉直径。研究结果表明通过视网膜功能成像可以检测糖尿病患者的视网膜氧代谢和灌注率等参数的临床变化,帮助医生更好地观察、评估糖尿病患者视网膜微血管的病理改变,并在糖尿病患者眼科并发症的早期诊断和预后评估方面具有一定的应用潜力。
Abstract
In this study, via the retinal functional imaging device, not only the structural information of the retina is imaged, but also the functional information such as the retinal oxygen saturation and vessel diameter is imaged and measured noninvasively and quantitatively. By comparing quantitatively the functional imaging results of diabetes patients and healthy controls, significantly elevated arterial oxygen saturation and arterial-venous oxygen saturation difference are found in diabetes patients. The area of the foveal avascular zone is also significantly increased in diabetes patients. The result also shows that there are significant differences between the average diameters of arteries and veins both in diabetes patients and healthy controls, and the arterial diameter is always larger than the venous diameter. The study demonstrates that by using the retinal functional imaging method, the clinical changes of retinal oxygen metabolism as well as the perfusion rate in diabetes patients can be detected, which helps doctors to better observe and evaluate the pathological changes of the retinal microvessels in diabetes patients. In addition, the retinal functional imaging technique has the application potential for the early diagnosis and prognostic evaluation of ophthalmic complications associated with diabetes.

邹达, 王珂欣, 刘刚军, 任秋实, 卢闫晔. 糖尿病患者视网膜血氧饱和度及血管直径变化的无创测量[J]. 激光与光电子学进展, 2020, 57(5): 051701. Da Zou, Kexin Wang, Gangjun Liu, Qiushi Ren, Yanye Lu. Noninvasive Measurement of Retinal Oxygen Saturation and Vessel Diameter Changes in Diabetes Mellitus Patients[J]. Laser & Optoelectronics Progress, 2020, 57(5): 051701.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!