Chinese Optics Letters, 2020, 18 (2): 021402, Published Online: Jan. 17, 2020  

Alignment and efficiency-monitoring method of high-power fiber-to-fiber coupling Download: 646次

Author Affiliations
1 MIIT Key Laboratory of Advanced Solid Laser, Nanjing University of Science and Technology, Nanjing 210094, China
2 School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing 210094, China
Abstract
High-power fiber-to-fiber coupling is extensively used in fiber laser applications, and its performance is determined by coupling efficiency. We demonstrate a novel method for alignment and monitoring efficiency by detecting backscattering power at the fiber end cap. The relationship between alignment error and backscattering power is determined by simulations and experiments. Through this method, a state-of-the-art kW-level fiber-to-fiber optic switch is developed (transmission efficiency >97%). It performs well for longer than 60 min. To the best of our knowledge, it is the first time to establish the mathematical model based on this method. Our results can provide guidance in high-power fiber-to-fiber coupling.

Qingqing Kong, Yiqiu Jing, Hua Shen, Shiwei Deng, Zhigang Han, Rihong Zhu. Alignment and efficiency-monitoring method of high-power fiber-to-fiber coupling[J]. Chinese Optics Letters, 2020, 18(2): 021402.