光学学报, 2018, 38 (3): 0332001, 网络出版: 2018-03-20   

短磁聚焦时间展宽分幅变像管成像性能及像差分析

Analysis of Imaging Performance and Aberration of Pulse-Dilation Framing Converter Using Short Magnetic Focusing
作者单位
桂林电子科技大学教学实践部, 广西 桂林 541004
摘要
分幅变像管是惯性约束聚变诊断实验中重要的二维空间分辨诊断设备。为研究短磁聚焦时间展宽分幅变像管的成像性能, 通过计算像管中电子运动轨迹和成像分布来模拟空间分辨率和成像面, 并采用像差理论展开分析。结果表明, 短磁聚焦成像系统的球差和场曲是造成像管空间分辨性能下降的主要因素, 单/双透镜像管球差系数分别为0.229和0.07, 场曲分别为0.021和0.009。球差系数和场曲越小, 像管的成像性能越好。
Abstract
The framing converter is an important two-dimensional spatial resolution diagnostic device in the inertial confinement fusion experiment. In order to study the imaging performance of pulse-dilation framing converter using short magnetic focusing, the spatial resolution and imaging surface are simulated by the electron motion trajectory and imaging distribution of the converter, and the aberration theory is used for analysis. The result shows that the spherical aberration and field curvature of short magnetic focused system are the main reasons for the loss of spatial resolution, the spherical aberration of the single/double lenses tube are 0.229 and 0.07, the field curvature are 0.021 and 0.009, respectively. The smaller spherical aberration and field curvature are, the better imaging performance of the tube is.

白雁力, 姚荣彬, 高海英, 党选举, 何国民. 短磁聚焦时间展宽分幅变像管成像性能及像差分析[J]. 光学学报, 2018, 38(3): 0332001. Bai Yanli, Yao Rongbin, Gao Haiying, Dang Xuanju, He Guomin. Analysis of Imaging Performance and Aberration of Pulse-Dilation Framing Converter Using Short Magnetic Focusing[J]. Acta Optica Sinica, 2018, 38(3): 0332001.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote