激光与光电子学进展, 2017, 54 (10): 101407, 网络出版: 2017-10-09  

时间分辨的脉冲氙灯光谱测试与分析 下载: 517次

Testing and Analysis of Time Resolved Pulse Xenon Lamp Spectrum
作者单位
1 中国工程物理研究院上海激光等离子体研究所, 上海 201800
2 中国科学院上海光学精密机械研究所, 上海 201800
摘要
高功率激光装置中的片状放大器普遍采用高功率脉冲氙灯作为抽运源, 氙灯的辐射光谱与片状放大器的增益性能密切相关。基于暗室中搭建的时间分辨率为2 μs的氙灯光谱测试系统, 测试氙灯在不同放电时刻的辐射光谱。结果表明: 相同电流密度对应的上升沿、下降沿时刻的氙灯辐射光谱存在显著差别, 上升沿光谱的分立谱明显; 当电流密度为0.866 kA·cm-2时, 如果不施加预电离, 上升沿的辐射光谱能量比下降沿低48%, 施加预电离后这种差距缩小至24%; 预电离可以有效提高上升沿时刻的光谱强度, 是提高氙灯辐射效率的有效途径之一; 对氙灯辐射光谱的原模型进行修正, 可使其与测试光谱数据更吻合。
Abstract
High power pulse xenon lamps are usually used as the pumping source for slab amplifiers in high power laser facilities. The spectrum of xenon lamps is strongly linked to the gain performance of slab amplifiers. A spectrum testing system in a dark room with the time resolution of 2 μs is built to test the xenon lamp spectra at different discharging time. The results show that the xenon lamp gives quite different spectra for rising and falling edges of the current waveform with the same current density. The rising edge spectrum has many obvious discrete spectra. If no pre-ionization is applied, the radiation spectrum energy at the rising edge is 48% lower than that at the falling edge when the current density is 0.866 kA·cm-2. If pre-ionization is applied, the difference reduces to 24%. The pre-ionization can effectively increase the radiated energy of the rising edge, and the pre-ionization is an effective way to increase the radiation efficiency of the xenon lamp. The original xenon lamp radiation spectrum model is modified to agree with the experimental spectral data well.

孙正飞, 梁海荣, 王利, 刘建军, 周申蕾, 李海兵, 朱俭. 时间分辨的脉冲氙灯光谱测试与分析[J]. 激光与光电子学进展, 2017, 54(10): 101407. Sun Zhengfei, Liang Hairong, Wang Li, Liu Jianjun, Zhou Shenlei, Li Haibing, Zhu Jian. Testing and Analysis of Time Resolved Pulse Xenon Lamp Spectrum[J]. Laser & Optoelectronics Progress, 2017, 54(10): 101407.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!