光学 精密工程, 2013, 21 (7): 1651, 网络出版: 2013-08-05   

激光诱导击穿光谱法测量煤粉流的控制因素

Controllable factors in detection of pulverized coal flow with LIBS
作者单位
1 广东电网公司 电力科学研究院, 广东 广州 510600
2 华南理工大学 电力学院, 广东 广州 510640
摘要
用激光诱导击穿光谱(LIBS)法直接检测煤粉流时需要对主要控制因素进行优化, 本文采用正交实验法考察了3个主要控制因素:功率密度、积分延迟时间和单位截面流量对LIBS测量煤粉流的影响。选用粒径小于0.2 mm的煤粉作为实验样品进行了统计分析和方差分析。结果显示:在实验所选取的参数范围内, 功率密度、积分延迟时间对有效激发率有显著影响, 单位截面流量的影响程度最低。优化后的方案为:功率密度9.4×1011 W/cm2, 积分延迟时间1 500 ns, 煤粉流量根据经济性原则在合理范围内选取。得到的结果表明该方法可用于指导煤粉流的实际在线测量。
Abstract
It is necessary to optimize operable factors in measurement of pulverized coal flow by Laser-induced Breakdown Spectroscopy(LIBS). Therefore, this paper investigated the effects of three main operable factors, irradiance, integration delay time and the rate of flow per unit area on the measurement of pulverized coal flow by LIBS based on orthogonal experiments. Pulverized coal was chosen for the experimental sample and the statistic analysis and variance analysis were performed. Experiment indicates that the irradiance and integration delay time are two remarkable factors for the effective excitation rate and the following is the rate of flow per unit area. The optimum parameters of control from the experiment are the irradiance of 9.4×1011 W/cm2 , the integration delay time of 1 500 ns, and the rate of flow is selected reasonably based on economy principles. The results obtained demonstrate that the method can direct the practical measurement of pulverized coal flows in real time.

陈世和, 陆继东, 张博, 陈华忠, 姚顺春, 李军, 潘刚, 张曦. 激光诱导击穿光谱法测量煤粉流的控制因素[J]. 光学 精密工程, 2013, 21(7): 1651. CHEN Shi-he, LU Ji-dong, ZHANG Bo, CHEN Hua-zhong, YAO Shun-chun, LI Jun, PAN Gang, ZHANG Xi. Controllable factors in detection of pulverized coal flow with LIBS[J]. Optics and Precision Engineering, 2013, 21(7): 1651.

本文已被 6 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!