激光技术, 2017, 41 (4): 521, 网络出版: 2017-08-09  

一种激光三角测量的标定方法及误差分析

Calibration method and error analysis of laser triangulation measurement
作者单位
1 南京航空航天大学 航天学院, 南京 210016
2 航天恒星科技有限公司 导航事业部, 北京 100086
3 中国人民解放军 91362部队, 舟山 316200
摘要
为了解决激光三角测量法在标定时, 不能直接准确地测量激光器端口与标定物的距离的问题, 采用了一种基于距离差进行标定的方法。该方法利用标定物移动的距离作为标定输入, 改进了测量系统的标定方法;采用高斯-牛顿迭代法计算测量系统的参量, 分析了测量系统在标定时可能产生的激光像点提取误差和非垂直误差。结果表明,测量距离的精度可达到4.000mm。该方法能够准确标定激光三角测量系统的参量。
Abstract
In order to solve the problem that the distance between laser port and calibration object couldn’t be measured directly and accurately, a new method based on distance difference of calibration was presented. The moving distance of calibration object was used as the calibration input to improve the traditional calibration method of measurement system. Gaussian-Newton iterative method was used to calculate the parameters of measurement system. The extraction error and non-vertical error of laser image point were analyzed. The results show that the precision can reach 4.000mm. The method can be used to calibrate the distance between calibration object and laser port accurately.