Chinese Optics Letters, 2019, 17 (4): 041201, Published Online: Apr. 3, 2019  

A miniaturized system for measurement of the refractive index of sub-microliter liquid Download: 691次

Author Affiliations
1 Institute of Biomedical Optics and Optometry, Shanghai Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, Shanghai 200093, China
2 Beckman Laser Institute and Center for Biomedical Engineering, University of California, Irvine, CA 92612, USA
3 Systems Engineering Institute, University of Applied Sciences Western Switzerland, Sion 1950, Switzerland
Abstract
This study introduced the research and development of a portable and miniaturized system for the measurement of the refractive index of sub-microliter liquid based on a microfluidic chip. A technical method of double-beam interference, was proposed for use in the measurement. Based on this, by using a laser diode as a light source, changes in the refractive index were calculated by utilizing a complementary metal–oxide–semiconductor to detect the movement of interference fringes of the liquid. Firstly, this study simulated the effects of influencing factors on the interference infringes of two Gaussian beams, such as their spot sizes, distance between two beam spots, and detection range. Secondly, this research introduced the system design and construction of the double-beam interference method and analyzed the results of refractive index tests on sub-microliter aqueous glucose solutions with different concentrations. The measurement accuracy reached 10 4 refractive index units. This system has a compact structure and is rendered portable by using batteries for its power supply. The entire system is designed to be a double Z-shaped structure with a length of about 15 cm, a width of 5 cm, and a height of about 10 cm. It can be used to measure changes in the refractive index of sub-microliter to nanoliter liquids based on the use of a microfluidic chip.

Minghui Chen, Wenyu Jia, Jintao He, Martial Geiser, Gang Zheng. A miniaturized system for measurement of the refractive index of sub-microliter liquid[J]. Chinese Optics Letters, 2019, 17(4): 041201.

引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!