基于空气隙棱镜实现布鲁斯特角型偏振器消光比测量

Measurement of Extinction Ratio of Brewster Angle Polarizer Based on Air Gap Prism
常闪闪 1,2,3,*麻云凤 1,2,3廖利芬 1,2赵鹏 1,2程旺 1,2樊仲维 1,2,3
作者单位
1 中国科学院光电研究院, 北京 100094
2 国家激光器件质量监督检验中心, 北京 100094
3 中国科学院大学, 北京 100049
摘要
布鲁斯特角型偏振器在高功率激光系统有着重要的应用。为了真实反映布鲁斯特角型偏振器的性能, 分析并成功搭建了基于空气隙棱镜的消光比测量系统。采用光强同时测量的方法, 测量过程系统起偏器、样品、检偏器方位角固定, 引起误差的因素较少。通过限制入射光光束直径和探测器的位置, 提高检偏器反射出光方向的偏光性能, 提高测试精度; 在样品定位的过程中, 对光源进行实时监测, 降低测量随机误差。理论分析, 系统精度越高, 系统误差越大。当系统精度为 40 dB, 系统误差约 2%。对一样品进行 10次测量, 消光比平均值为 31.1 dB, 系统误差小于 1%, 随机误差小于 1%。
Abstract
Brewster angle polarizers have important applications in high power laser systems. To truly reflect the performance of the Brewster angular polarizer, an extinction ratio measurement system based on an air gap prism was analyzed and successfully constructed. The azimuth angles of the polarizer and sample were fixed in the measurement process by using the method of simultaneous measurement of light intensity, and the factors causing errors were reduced. When the diameter of the incident beam and position of the detector were limited, both the polarization performance of the analyzer reflecting the direction of light and the test accuracy were improved. During sample positioning, the light source was monitored in real time to reduce the measurement random error. Theoretical analysis showed that the higher the system accuracy, the greater was the system error. When the system accuracy was 40 dB, the system error was approximately 2%. Ten measurements were conducted on a sample with an average extinction ratio of 31.1 dB, a systematic error of less than 1%, and a random error of less than 1%.

常闪闪, 麻云凤, 廖利芬, 赵鹏, 程旺, 樊仲维. 基于空气隙棱镜实现布鲁斯特角型偏振器消光比测量[J]. 红外技术, 2019, 41(9): 882. CHANG Shanshan, MA Yunfeng, LIAO Lifen, ZHAO Peng, CHENG Wang, FAN Zhongwei. Measurement of Extinction Ratio of Brewster Angle Polarizer Based on Air Gap Prism[J]. Infrared Technology, 2019, 41(9): 882.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!