光谱学与光谱分析, 2015, 35 (6): 1639, 网络出版: 2015-06-11   

基于可调谐激光吸收光谱技术的脱硝过程中微量逃逸氨气检测实验研究

The Research for Trace Ammonia Escape Monitoring System Based on Tunable Diode Laser Absorption Spectroscopy
作者单位
浙江大学能源清洁利用国家重点实验室, 浙江 杭州 310027
摘要
为了对电厂脱硝过程中逃逸的微量氨气进行在线检测, 实验室采用可调谐激光吸收光谱技术对常温常压下以及不同温度下的低浓度氨气进行了测量试验, 其中电厂逃逸氨气检测处温度约为650 K。 通过分析近红外波段的氨气吸收谱线, 并考虑实际测量环境H2O和CO2等浓度很大的气体吸收谱线的干扰, 实验选取2.25 μm附近的ν2+ν3谱线作为浓度检测谱线。 为了验证所选谱线对低浓度NH3的测量能力, 实验对H2O, CO2和NH3的吸收谱线进行模拟, 发现低浓度NH3受较大浓度的H2O和CO2谱线的干扰较小, 尤其是CO2谱线的干扰可以忽略不计, 且2.25 μm处谱线强度远远大于通讯波段1.53 μm处的谱线。 基于新型Herriott池以及高温管式炉, 结合可调谐激光吸收光谱中的直接吸收技术和波长调制技术, 实现了对不同温度下超低浓度NH3的高分辨率快速检测。 常温常压下其线型函数可以利用洛伦兹线型来近似描述, 直接吸收测量技术可以使探测极限降低到0.225×10-6。 通过采用简单降噪处理技术如多次平均、 简单小波分析等, 得到不同温度下的谐波信号与浓度具有良好的线性关系, 为采用可调谐激光吸收光谱技术进行现场低浓度逃逸氨气检测提供了很好的依据。
Abstract
In order to on-line measure the trace ammonia slip of the commercial power plant in the future, this research seeks to measure the trace ammonia by using tunable diode laser absorption spectroscopy under ambient temperature and pressure, and at different temperatures, and the measuring temperature is about 650 K in the power plant. In recent years lasers have become commercially available in the near-infrared where the transitions are much stronger, and ammonia’s spectroscopy is pretty complicated and the overlapping lines are difficult to resolve. A group of ammonia transitions near 4 433.5 cm-1 in the ν2+ν3 combination band have been thoroughly selected for detecting lower concentration by analyzing its absorption characteristic and considering other absorption interference in combustion gases where H2O and CO2 mole fraction are very large. To illustrate the potential for NH3 concentration measurements, predictions for NH3, H2O and CO2 are simultaneously simulated, NH3 absorption lines near 4 433.5 cm-1 wavelength meet weaker H2O absorption than the commercial NH3 lines, and there is almost no CO2 absorption, all the parameters are based on the HITRAN database, and an improved detection limit was obtained for interference-free NH3 monitoring, this 2.25 μm band has line strengths several times larger than absorption lines in the 1.53 μm band which was often used by NH3 sensors for emission monitoring and analyzing. The measurement system was developed with a new Herriott cell and a heated gas cell realizing fast absorption measurements of high resolution, and combined with direct absorption and wavelenguh modulation based on tunable diode laser absorption spectroscopy at different temperatures. The lorentzian line shape is dominant at ambient temperature and pressure, and the estimated detectivity is approximately 0.225×10-6 (SNR=1) for the directed absorption spectroscopy, assuming a noise-equivalent absorbance of 1×10-4. The heated cell experiments with controlled the temperature were performed to validate the sensing strategy. Here the Wavelength Modulation Spectroscopy (WMS) strategy was usually used to measure lower gas concentration for high noise immunity to the non-absorption transmission losses. The great agreement 2f signal with the calibrated concentration is within the uncertainty at different temperatures by using simple digital signal processing such as multiple averages, wavelet analysis and so on. The denoise processing has a great advantage in application and implementation over other noise suppression techniques. The result provided a good basis for trace ammonia escape detection based on tunable diode laser absorption spectroscopy.

张立芳, 王飞, 俞李斌, 严建华, 岑可法. 基于可调谐激光吸收光谱技术的脱硝过程中微量逃逸氨气检测实验研究[J]. 光谱学与光谱分析, 2015, 35(6): 1639. ZHANG Li-fang, WANG Fei, YU Li-bin, YAN Jian-hua, CEN Ke-fa. The Research for Trace Ammonia Escape Monitoring System Based on Tunable Diode Laser Absorption Spectroscopy[J]. Spectroscopy and Spectral Analysis, 2015, 35(6): 1639.

本文已被 6 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!