摘要

分幅变像管是惯性约束聚变诊断实验中重要的二维空间分辨诊断设备。为研究短磁聚焦时间展宽分幅变像管的成像性能, 通过计算像管中电子运动轨迹和成像分布来模拟空间分辨率和成像面, 并采用像差理论展开分析。结果表明, 短磁聚焦成像系统的球差和场曲是造成像管空间分辨性能下降的主要因素, 单/双透镜像管球差系数分别为0.229和0.07, 场曲分别为0.021和0.009。球差系数和场曲越小, 像管的成像性能越好。

Abstract

The framing converter is an important two-dimensional spatial resolution diagnostic device in the inertial confinement fusion experiment. In order to study the imaging performance of pulse-dilation framing converter using short magnetic focusing, the spatial resolution and imaging surface are simulated by the electron motion trajectory and imaging distribution of the converter, and the aberration theory is used for analysis. The result shows that the spherical aberration and field curvature of short magnetic focused system are the main reasons for the loss of spatial resolution, the spherical aberration of the single/double lenses tube are 0.229 and 0.07, the field curvature are 0.021 and 0.009, respectively. The smaller spherical aberration and field curvature are, the better imaging performance of the tube is.

Newport宣传-MKS新实验室计划
补充资料

中图分类号:TN143;O536

DOI:10.3788/aos201838.0332001

所属栏目:超快光学

基金项目:国家自然科学基金(61263013)、广西自然科学基金重点项目(2016GXNSFDA380001)、广西高校中青年教师基础能力提升项目(2017KY0199)、广西教育厅高校科学技术研究项目(YB2014131)

收稿日期:2017-09-08

修改稿日期:2017-10-16

网络出版日期:--

作者单位    点击查看

白雁力:桂林电子科技大学教学实践部, 广西 桂林 541004
姚荣彬:桂林电子科技大学教学实践部, 广西 桂林 541004
高海英:桂林电子科技大学教学实践部, 广西 桂林 541004
党选举:桂林电子科技大学教学实践部, 广西 桂林 541004
何国民:桂林电子科技大学教学实践部, 广西 桂林 541004

联系人作者:白雁力(bayaly@guet.edu.cn)

备注:白雁力(1979-), 男, 博士, 副教授, 主要从事超快诊断技术方面的研究。E-mail: bayaly@guet.edu.cn

【1】Oertel J A, Aragonez R, Archuleta T, et al. Gated X-ray detector for the National Ignition Facility[J]. Review of Scientific Instruments, 2006, 77(10): 10E308.

【2】Bell P M, Bradley D K, Kilkenny J D, et al. Radiation hardening of gated X-ray imagers for the National Ignition Facility[J]. Review of Scientific Instruments, 2010, 81(10): 10E540.

【3】Cai H Z, Liu J Y, Peng X, et al. Note: non-gain microchannel plate gated framing camera[J]. Review of Scientific Instruments, 2011, 82(5): 056102.

【4】Cai H Z, Liu J Y, Peng X, et al. Large-format microchannel plate gated framing camera[J]. Nuclear Instruments & Methods in Physics Research A, 2012, 677: 14-17.

【5】Cai H Z, Liu J Y, Peng X, et al. Design of an X-ray framing camera with wide microstrip line[J]. Chinese Journal of Lasers, 2012, 39(1): 0117001.
蔡厚智, 刘进元, 彭翔, 等. 宽微带X射线分幅相机的研制[J]. 中国激光, 2012, 39(1): 0117001.

【6】Hilsabeck T J, Hares J D, Kilkenny J D, et al. Pulse-dilation enhanced gated optical imager with 5 ps resolution[J]. Review of Scientific Instruments, 2010, 81(10): 10E317.

【7】Nagel S R, Hilsabeck T J, Bell P M, et al. Dilation X-ray imager a new/faster gated X-ray imager for the NIF[J]. Review of Scientific Instruments, 2012, 83(10): 10E116.

【8】Nagel S R, Hilsabeck T J, Bell P M, et al. Investigating high speed phenomena in laser plasma interactions using dilation X-ray imager[J]. Review of Scientific Instruments, 2014, 85(11): 11E504.

【9】Bai Y L, Long J H, Cai H Z, et al. Simulated and measured spatial resolution of framing converter using short magnetic focusing[J]. Journal of Shenzhen University (Science and Engineering), 2015, 32(2): 178-182.
白雁力, 龙井华, 蔡厚智, 等. 短磁聚焦分幅变像管空间分辨率的模拟与测试[J]. 深圳大学学报(理工版), 2015, 32(2): 178-182.

【10】Bai Y L, Long J H, Liu J Y, et al. Demonstration of 11-ps exposure time of a framing camera using pulse-dilation technology and a magnetic lens[J]. Optical Engineering, 2015, 54(12): 124103.

【11】Cai H Z, Zhao X, Liu J Y, et al. Dilation framing camera with 4 ps resolution[J]. APL Photonics, 2016, 1(1): 016101.

【12】Lei Y F, Long J H, Liu J Y, et al. Design of framing image tube with large detection area[J]. Chinese Journal of Lasers, 2016, 43(9): 0904009.
雷云飞, 龙井华, 刘进元, 等. 大探测面积分幅变像管设计[J]. 中国激光, 2016, 43(9): 0904009.

【13】Hao Y D, Yuan Y T, Miao W Y. Effect of image distortion of X-ray streak camera in fluid instability experiment[J]. Infrared and Laser Engineering, 2012, 41(6): 1503-1507.
郝轶聃, 袁永腾, 缪文勇. 流体不稳定性实验中条纹相机像场畸变的影响[J]. 红外与激光工程, 2012, 41(6): 1503-1507.

【14】Shao J Z. Principle of electronic ion optical instrument[M]. Hangzhou: Zhejiang University Press, 1989.
邵健中. 电子离子光学仪器原理[M]. 杭州: 浙江大学出版社, 1989.

【15】Zhao G J. Electron Optics[M]. Beijing: National Defense Industry Press, 1985.
赵国骏. 电子光学[M]. 北京: 国防工业出版社, 1985.

【16】Shi H D, Jiang H L, Zhang X, et al. Research on freeform optical system aberration characteristic based on vector aberration[J]. Acta Optica Sinica, 2015, 35(12): 1208003.
史浩东, 姜会林, 张新, 等. 基于矢量像差的自由曲面光学系统像差特性研究[J]. 光学学报, 2015, 35(12): 1208003.

引用该论文

Bai Yanli,Yao Rongbin,Gao Haiying,Dang Xuanju,He Guomin. Analysis of Imaging Performance and Aberration of Pulse-Dilation Framing Converter Using Short Magnetic Focusing[J]. Acta Optica Sinica, 2018, 38(3): 0332001

白雁力,姚荣彬,高海英,党选举,何国民. 短磁聚焦时间展宽分幅变像管成像性能及像差分析[J]. 光学学报, 2018, 38(3): 0332001

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF