光电工程, 2016, 43 (3): 41, 网络出版: 2016-09-12  

布里渊传感系统脉冲光源消光比自动控制方法

An Auto-control Method of Pulsed Light Extinction Ratio in the Brillouin Sensing System
作者单位
1 中国计量学院计量测试工程学院,杭州 310018
2 上海光学精密机械研究所,上海 201800
摘要
针对布里渊光时域反射型 (BOTDR)分布式光纤传感系统中脉冲光源消光比易受偏置电压漂移影响的问题,本文提出了一种结合双电极串联结构电光调制器(EOM)及“扫描.步进跟踪”算法的脉冲光源消光比自动控制方法。实验结果表明,该方法可将 EOM输出脉冲光的消光比稳定在 50 dB以上。在 150 min的测试时间里,输出脉冲光消光比的最大值为 52.4 dB,最小值为 51.1 dB,波动值仅为 1.3 dB。该方法对 BOTDR光纤传感系统及高功率激光驱动装置等设备中脉冲光源性能的提升具有重要意义。
Abstract
A novel method to control the pulsed light extinction ratio automatically, which combines a double electrode series structure EOM with “scanning & step-tracking” algorithm, is proposed. It aims to address the problem that extinction ratio of pulsed light is affected by bias voltage shifting in a Brillouin Optical-fiber Time-domain Reflectometry (BOTDR) based on distributed optical fiber sensing system. Based on the method, some experiments are conducted and important conclusions are deduced. The results show that it could keep the extinction ratio of pulsed light above 50 dB steadily. The fluctuation of extinction ratio is only 1.3 dB, maximum value of extinction ratio is 52.4 dB and the minimum value is 51.1 dB. It is indicated that the proposed method will have important significance for enhancing the performance of pulsed light source in BOTDR optical fiber sensing system and high power laser driving device.
参考文献

[1] 胡佳惠,张大伟,陶春先,等 . 布里渊散射的分布式光纤温度传感器的研究进展 [J].激光杂志, 2011,32(6):1-3. HU Jiahui,ZHANG Dawei,TAO Chunxian,et al. Research and development of distributed optic fiber sensors based on Brillouin scattering [J]. Laser Journal,2011,32(6):1-3.

[2] 洪小斌,郭宏翔,伍剑 . 基于布里渊时域分析的分布式光纤传感入侵定位系统 [J].中国激光, 2010,37(4):1037-1041. HONG Xiaobin,GUO Hongxiang,WU Jian. A Brillouin Optical Time Domain Analysis Based Dstributed Fiber Optic Intrusion Sensor System [J]. Chinese Journal of Laser,2010,37(4):1037-1042.

[3] 胡佳成,陈福昌,林尊琪 . 基于布里渊光时域反射的分布式光纤传感入侵定位检测系统 [J].光电子 ·激光, 2012,23(5): 944-949. HU Jiacheng,CHEN Fuchang,LI Zunqi. A Brillouin optical time-domain reflectometr based distributed fiber optic instrusion sensor system [J]. Journal of Optoelectronics·Laser,2012,23(5):944-949.

[4] 陈新睿,韩敬华,牛瑞华,等 . 铌酸锂电光调制器的温度特性研究 [J].激光杂志, 2014,35(2):14-15. CHEN Xinrui,HAN Jinhua,NIU Ruihua,et al. The research on temperature properties of the LiNbO3 electro-optic modulator [J]. Laser Journal,2014,35(2):14-15.

[5] YIN Chengqun,LIU Liguo,Lü Anqiang,et al. EOM bias control scheme in BOTDR system [C]// The Ninth International Conference on Electronic Measurement & Instruments,Beijing,China,August,16-18,2009:378-381.

[6] Pak S Cho,Jaco B Khurgin,Isaac Shpantzer. Closed-loop bias control of optical quadrature modulator [J]. IEEE Photonics Technoloy Letters(S1943-0655),2006,18(21):2209-2211.

[7] 樊理文,孟洲,孙乔,等 . 马赫-曾德尔电光调制器工作点自动控制 [J].中国激光, 2014,41(9):09050011-09020015. FAN Liwen,MENG Zhou,SUN Qiao,et al. Operating Points Control for Mach-Zehnder Electro-Optic Modulato [J]. Chinese Journal of Laser,2014,41(9):09050011-09020015.

[8] TANG Yanfeng,LI Hongzuo,LI Rui,et al. Research of Auto Control About Bias voltage of high speed and Power Electro-optic Modulator [C]// International Conference on Electronics and Optoelectronics,Dalian,China,April 8-10, 2011,V4:118-121.

[9] 闻和,葛逸宏,姜欢,等. 基于相干自混频原理的马赫 -曾德尔调制器偏置点的监测 [J].中国激光, 2009,36(8):2036-2041. WEN He,GE Yihong,JIANG Huan,et al. Monitoring Bias Offset Drift of Mach-Zehnder Modulator Based on Coherent Hybrid Scheme [J]. Chinese Journal of Laser,2009,36(8):2036-2041.

[10] 赵志儒. 电光调制器的自动增益和自动控制偏置系统 [D].北京:北京邮电大学, 2010:1-56. ZHAO Zhiru. Electro-Optic Modulator Of The Automatic Gain And Automatic Bias Control Syatem [D]. Beijing:Beijing University of Posts and Telecommunications,2010:1-56.

[11] Sally M Maughan,Huai H Kee,Trevor P Newson. 57 km single-ended spontaneous Brillouin-based distributed fiber temperature sensor using microwave coherent detection [J]. Optics Letters(S1539-4794),2001,26(6):331-333.

[12] Sally M Maughan,Huai H Kee,Trevor P Newson. Simultaneous distributed fibre temperature and strain sensor using microwave coherent detection of spontaneous Brillouin backscatterr [J]. Measurement Science and Technology(S0957-0233),2001,12: 834-842.

胡佳成, 王婵媛, 李国扬, 沈小燕. 布里渊传感系统脉冲光源消光比自动控制方法[J]. 光电工程, 2016, 43(3): 41. HU Jiacheng, WANG Chanyuan, LI Guoyang, SHEN Xiaoyan. An Auto-control Method of Pulsed Light Extinction Ratio in the Brillouin Sensing System[J]. Opto-Electronic Engineering, 2016, 43(3): 41.