Author Affiliations
Abstract
School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
The property of maintaining the lens state of the liquid crystal (LC) lens during the switching between positive and negative lens states is made use of in the fast acquirement of multi-focus images without magnification change. A depth from focus (DFF) pipeline that can generate a low-error depth map and an all-in-focus image is proposed. The depth of the scene is then obtained via DFF pipeline from the captured images. The depth sensor proposed in this paper has the advantages of simple structure, low cost, and long service life.
Liquid crystal lens transient property depth from focus depth sensor Photonic Sensors
2023, 13(2): 230230
Author Affiliations
Abstract
Key Laboratory of Light Field Manipulation and Information Acquisition, Ministry of Industry and Information Technology, Shaanxi Key Laboratory of Optical Information Technology, School of Physical Science and Technology, Northwestern Polytechnical University, Xi’an 710129, China
We numerically demonstrate that the tight focusing of Bessel beams can generate focal fields with an ultra-long depth of focus (DOF). The ultra-long focal field can be controlled by appropriately regulating the order of the Bessel function and the polarization. An optical needle and an optical dark channel with nearly DOF are generated. The optical needle has a DOF of and a super-diffraction-limited focal spot with the size of . The dark channel has a full-width at half-maximum of and a DOF of . Furthermore, the oscillating focal field with an ultra-long DOF can be also generated by merely changing the order of the input Bessel beam. Our results are expected to contribute to potential applications in optical tweezers, atom guidance and capture, and laser processing.
Bessel beam vector beam tight focusing depth of focus Chinese Optics Letters
2023, 21(7): 072601
红外与激光工程
2023, 52(4): 20220686
李世光 1,2,3,*†郭磊 1,2,3,**†曾海峰 1,2,3戢逸云 1,2,3[ ... ]肖燕青 3
1 中国科学院大学集成电路学院,北京 100049
2 中国科学院微电子研究所成果转化部,北京 100029
3 江苏影速集成电路装备股份有限公司,江苏 徐州 221300
光刻技术中的聚焦控制对曝光质量有直接的影响。曝光过程中,为保证良率,曝光区域需要时刻处于焦深范围内。通过建立数学模型,探讨了光刻机系统总离焦量与产品良率的关系,而光刻机的总离焦量又是多种离焦误差共同作用的结果。研究了先进的双工件台光刻系统和应用于掩模板制造的数字微反射镜装置光刻系统的工作流程,分析了与聚焦控制密切相关的若干离焦误差。在诸多误差因素当中,调焦调平传感器对总离焦量有着重要影响,光刻机的聚焦控制很大程度依赖于调焦调平传感器的准确测量。对Canon、Nikon和ASML的调焦调平传感器进行了调研,对比研究各自的传感器原理和结构,为光刻机的聚焦控制分析提供参考。
光刻 焦深 聚焦控制 良率 离焦误差 调焦调平 激光与光电子学进展
2022, 59(9): 0922016
Author Affiliations
Abstract
School of Electronic Engineering, Beijing Key Laboratory of Space-Ground Interconnection and Convergence, and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876, China
Underwater optical wireless communication, which is useful for oceanography, environmental monitoring, and underwater surveillance, suffers the limit of the absorption attenuation and Mie–Rayleigh scattering of the lights. Here, Bessel-like beams generated by a fiber microaxicon is utilized for underwater wireless propagation. Underwater, the cone angle for generating Bessel-like beams starts from 46°, which is smaller than that in air for Bessel-like beams. When the cone angle of the fiber microaxicons is about 140°, the depth of focus underwater, which is four times as long as the depth of focus in air, has enlarged about 28 µm, 36.12 µm, and 50.7 µm for 470 nm, 520 nm, and 632 nm visible lights. The transmission distance of the Bessel beams for visible lights has been simulated by using Henyey–Greenstein–Rayleigh phase function methods and spectral absorption by bio-optical model due to Monte Carlo methods. The results show that the propagation distance could reach 4000 m, which overcome the limit of the Mie–Rayleigh scattering and absorption attenuation underwater.
Bessel-like beams depth of focus underwater optical wireless communication Chinese Optics Letters
2022, 20(7): 072601
1 有研科技集团有限公司国家有色金属及电子材料分析测试中心,北京 100088
2 国合通用测试评价认证股份公司,北京 101400
3 北京有色金属研究总院,北京100088
4 山东东仪光电仪器有限公司,山东 烟台 264003
5 中国科学院山东综合技术转化中心烟台中心,山东 烟台 264003
6 中国科学院长春光学精密机械与物理研究所,吉林 长春 13033
基于自行设计搭建的远程激光诱导击穿光谱(LIBS)系统, 完成了远程LIBS的聚焦特性分析, 并对远程 LIBS技术应用于镍基高温合金成分分析的实验方法进行了研究。 该LIBS系统具备激光发射光路和信号采集光路同轴且独立变焦的特点, 通过自动聚焦, 可实现1~10 m的远程分析。 研究表明: 受激光聚焦焦深的影响, 等离子体光信号可探测范围随系统工作距离的增大而增大, 即系统对聚焦精确度的要求降低; 同时, 烧蚀斑点尺寸增大导致的功率密度减小及信号采集立体角的减小, 会使得谱线强度随工作距离的增大成四次方反比关系衰减。 分别使用无内标的标准曲线法和有内标的标准曲线法建立了GH4169镍基高温合金中Ni, Cr, Nb, Mo, Ti和Al六种元素的标准曲线, 有内标的标准曲线的拟合优度R2(0.999 7, 0.999 4, 0.998 7, 0.999 1, 0.998 1和0.999 7)明显优于无内标的标准曲线(0.953 2, 0.876 6, 0.897 4, 0.914 5, 0.938 4和0.991 6)。 对比了LIBS和X射线荧光光谱(XRF)两种分析技术, 对于常量元素Ni, Cr, Nb和Mo, 两种方法的相对标准偏差分别在1.74%~3.90%以及0.10%~0.52%, 相对误差分别在0.21%~0.92%以及0.64%~2.25%; 对于微量元素Ti和Al, 两种方法的相对标准偏差分别为5.58%, 4.15%以及2.39%, 5.64%, 相对误差分别为2.75%, 2.93%以及4.68%, 2.39%。 由于激光诱导等离子体的不稳定性、 烧蚀样品量少的特点, 远程LIBS方法的精密度稍逊于XRF方法, 但LIBS方法通过重复多次测量, 可以有效减小测量误差, 表明LIBS技术应用于镍基高温合金的远程在线分析具有一定的可行性。
激光诱导击穿光谱 远程 焦深 标准曲线法 Laser-induced breakdown spectroscopy Remote Depth of focus Standard curve method
浙江大学光电科学与工程学院, 浙江 杭州 310027
目前数码显微镜中常用的自动对焦方法分为主动式自动对焦和被动式自动对焦。主动式自动对焦依赖特定的传感器或者测距设备,通过主动发出光波并且接收反射回来的光波判断物体与对焦装置的距离,从而达到对焦目的;被动式自动对焦通过分析每个位置图像信息来判断对焦方向以及对焦位置,以达到对焦目的。被动式自动对焦由于其对结构的要求简单、成本较低,是数码显微镜最常用的自动对焦方法。主要介绍了应用于数码显微镜的自动对焦算法,简述了主动式与被动式自动对焦的原理以及发展方向,重点介绍了被动式自动对焦方法中的对焦深度法,分析了对焦深度法的两大关键技术,即清晰度评价函数及其对焦搜索算法。
成像系统 数码显微镜 自动对焦 对焦深度法 清晰度评价函数 激光与光电子学进展
2021, 58(4): 0400002
浙江大学光电科学与工程学院,现代光学仪器国家重点实验室, 浙江 杭州 310027
小型化探头是内窥光学相干层析成像(Optical coherence tomography, OCT)中的普遍需求。介绍了包括基于球透镜、光纤透镜、自聚焦光纤、自由曲面透镜、无透镜的OCT技术的发展历程,总结和比较了各种技术的优劣,为探头的小型化设计提出了建议。研究探头的焦深拓展技术对分辨人体内细胞的在体成像的发展具有重要意义。介绍了几种重要的适用于小型化探头的焦深拓展技术,其中基于模式干涉的探头由于易于制作、结构紧凑、传输效率高,同时具有可以优化工作距离、焦深和轴向光强均匀性的优点,在拓展小型化探头的焦深方面具有一定的发展潜力。
生物光子学 光学相干层析成像 内窥成像 光纤探头 模式干涉 焦深拓展