中国激光, 2008, 35 (5): 752, 网络出版: 2008-05-20   

激光测高仪中基于现场可编程门阵列的高精度飞行时间测量

High-Resolution Measurement of Flight Time for Laser Altimeter Based on Field Programmable Gate Array
作者单位
中国科学院安徽光学精密机械研究所, 安徽 合肥 230031
摘要
设计了在激光测高系统中基于单芯片现场可编程门阵列(FPGA)的高精度时间间隔测量模块。该模块采用高频计数器实现粗时间测量,差分延时线内插技术完成细时间测量,时间分辨率为300 ps。该芯片同时还集成了时序切割电路、回波脉宽测量和数据传输模块等。在环境温度20 ℃时对该测量模块进行精度测试,获得标准偏差为94.68 ps,转换成距离为1.42 cm。最后通过地面检测,整个系统在500 km范围内的一般条件下可获得测高精度±50 cm。
Abstract
A high-resolution flight time measurement system based on a single field programmable gate array (FPGA) in laser altimeter is designed. The time resolution of 300 ps is obtained, because the differential delay lines are used to perform interpolation and to realize the fine time measurement, and high frequency counter is designed to perform the coarse time measurement. The time splitting circuit, pulse width counter and data transmitter module are integrated in the same chip. At an ambient temperature of 20 ℃, we achieve a standard deviation of 94.68 ps which equals to 1.42 cm in distance. Furthermore, detection on the ground verifies the feasibility of measuring distance with ±50 cm resolution over 500 km ranges under general conditions.
参考文献

[1] . Timothy. Cole. NEAR laser rangefinder: A tool for the mapping and topologic study of asteroid 433 eros[J]. Johns Hopkins Appl. Technical Digest, 1998, 19(2): 142-157.

[2] . B. Abhire, X. Sun, R. S. Afzal. Mars orbiter laser altimeter: receiver model and performance analysis[J]. Appl. Opt., 2000, 39(15): 2449-2460.

[3] Huo Yujin, Chen Qiansong, Pan Zhiwen. Review on time-of-flight measurement of pulsed laser radar [J]. Laser & Infrared, 2001, 31(3):136~139
霍玉晶,陈千颂,潘志文. 脉冲激光雷达的时间间隔测量综述[J]. 激光与红外, 2001, 31(3):136~139

[4] . Kailisz. Review of methods for time interval measurements with picoseconds resolution[J]. Metrologia, 2004, 41: 17-32.

[5] . Nutt. Digital time intervalometer[J]. Rev. Sci. Instrum., 1968, 39(9): 1342-1345.

[6] . Kalisz, R. Szplet, R. Peka et al.. Single-chip low-cost time counter for distance measurements with 3 cm resolution[J]. J. Opt., 1998, 29(3): 199-205.

[7] . Kalisz, R. Szplet, R. Peka et al.. Single-chip interpolating time counter with 200-ps resolution and 43-s range[J]. IEEE Trans. Instrum. Meas., 1997, 46(4): 851-856.

[8] Chen Qiansong, Zhao Dalong, Yang Chenwei et al.. Study on self-triggering pulsed time-of-flight laser range finding [J]. Chinese J. Lasers, 2004, 31(6):745~748
陈千颂,赵大龙,杨成伟 等. 自触发脉冲飞行时间激光测距技术研究[J]. 中国激光, 2004, 31(6):745~748

[9] Qin Laigui, Huo Yujing, He Shufang. Study on pulsed laser range finder based on digital polarity correlation algorithm [J]. Chinese J. Lasers, 2006, 33(7):941~944
秦来贵,霍玉晶,何淑芳. 基于数字极性相关算法的激光脉冲测距[J]. 中国激光, 2006, 33(7):941~944

[10] Zhao Dong, Liu Liren, Wang Jiming et al.. A laser ranging method based on photon statistics [J]. Acta Optica Sinica, 2006, 26(7):1091~1096
赵栋,刘立人,王吉明 等. 基于光子数目比较的激光测距法[J]. 光学学报, 2006, 26(7):1091~1096

[11] Jixin Chen, Zhan Sui, Fushen Chen et al.. Output characteristic of Yb3+-doped fiber laser at different temperatures [J]. Chin. Opt. Lett., 2006, 4(3):173~174

姚萍萍, 赵欣, 张毅, 赵平建, 涂碧海. 激光测高仪中基于现场可编程门阵列的高精度飞行时间测量[J]. 中国激光, 2008, 35(5): 752. Yao Pingping, Zhao Xin, Zhang Yi, Zhao Pingjian, Tu Bihai. High-Resolution Measurement of Flight Time for Laser Altimeter Based on Field Programmable Gate Array[J]. Chinese Journal of Lasers, 2008, 35(5): 752.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!