光电工程, 2012, 39 (10): 78, 网络出版: 2012-11-22  

树脂传递模塑成型注模过程的光纤光栅监测

Monitoring the Injection Process of Resin Transfer Molding with Fiber Bragg Gratings
作者单位
沈阳航空航天大学航空航天学部, 沈阳 110136
摘要
有效监测树脂传递模塑成型 (RTM)的树脂注模过程对于生产大型共固化复合材料结构十分必要。本文重点讨论利用光栅传感器监测注模过程的树脂流动问题。本文在复合材料层的不同位置布置了 1个温度传感器用来监测温度, 2个应变传感器用来监测树脂流动前沿到达时间, 试验结果表明 50 min和 115 min时树脂流动前沿分别到达 No.1和 No.2应变传感器, 166 min时完成注模, 此时监测温度为最低的 24.59 ℃。光栅传感器完全可实现树脂传递模塑注模过程的监测。
Abstract
It is essential to monitor the resin injection process of Resin Transfer Molding (RTM) for manufacturing large integrated co-cured structures. This paper discusses the efforts in developing fiber Bragg sensors for monitoring the flow of the resin during the infusion process. Three Fiber Bragg Gratings (FBG) sensors are put into the composite layers at different location, one is used to monitor the temperature and the two others are used to detect the arrival of the resin flow front. The experimental results show that the arrival time of the resin flow front to the No.1 and No.2 sensor are 50 min and 115 min, respectively. The injection end time is 166 min at the maximum temperature of 24.59 ℃. The network of FBG sensors would be very useful to provide information of resin injection of RTM procession.
参考文献

[1] Simon Bickerton, Hubert C Stadtfeld, Karl V Steiner, et al. Design and application of actively controlled injection schemes for resin-transfer molding [J]. Composites Science and Technology(S0266-3538), 2001, 61(11): 1625–1637.

[2] Omar Restrepo, Kuang-Ting Hsiao, Alejandro Rodriguez b, et al. Development of adaptive injection flow rate and pressure control algorithms for resin transfer molding [J]. Composites: Part A(S1359-835X), 2007, 38A(6): 1547–1568.

[3] Dhiren Modi, Nuno Correia, Michael Johnson, et al. Active control of the vacuum infusion process [J]. Composites: Part A(S1359-835X), 2007, 38(5): 1271–1287.

[4] Amico S, Lekakou C. An experimental study of the permeability and capillary pressurein resin-transfer molding[J]. Composite Science and Technology(S0266-3538), 2001, 61(13): 1945–1959.

[5] Sozer E M, Tuncol G, Danisman M, et al. Constraints on monitoring resin flow in the resin transfer molding (RTM) process by using thermocouple sensors [J]. Composites Part A(S1359-835X), 2007, 38(5): 1363–1386.

[6] Skordos A A, Karkanas P I, Partridge I K. A dielectric sensor for measuring flow in resin transfer moulding [J]. Measurement Science and Technology(S1361-6501), 2000, 11(1): 25–31.

[7] Murat Danisman, Goker Tuncol, Alper Kaynar, et al. Monitoring of resin flow in the resin transfer molding (RTM) process using point-voltage sensors [J]. Composites Science and Technology(S0266-3538), 2007, 67(3/4): 367–379.

[8] Nedanov P, Advani S. A method to determine 3-D permeability of fibrous performs [J]. Journal of Composite Materials (S1530-793X), 2002, 36(2): 241–254.

[9] 张燕君, 娄俊波, 康瑞雪, 等. 新型分布式布喇格光纤光栅传感系统的研究 [J].光电工程, 2010, 37(1): 88–94. ZHANG Yan-jun, LOU Jun-bo, KANG Rui-xue, et al. Novel Distributed Sensor System V Based on Fiber Bragg Grating Sensing Technology [J]. Opto-Electronic Engineering, 2010, 37(1): 88–94.

[10] 冯艳, 李玉龙, 张华, 等. 埋入式光纤 Bragg光栅径向应力传感性能参数分析 [J].光电工程, 2011, 38(12): 104–109. FENG Yan, LI Yu-long, ZHANG Hua, et al. Parameter Analysis on the Radial Stress Transfer of Fiber Bragg Grating Embedded into Metal Beam [J]. Opto-Electronic Engineering, 2011, 38(12): 104–109.

[11] Lekakou S Cook, Deng Y, Ang T W, et al. Optical fibre sensor for monitoring flow and resin curing in composites manufacturing [J]. Composites: Part A(S1359-835X), 2006, 37(6): 934–938.

[12] Yingdan Zhu, Chang Wang, Jihui Wang. Long-period gratings in-situ Sensing for Flow Monitoring in Liquid Composite Molding [J]. Journal of Science and Technology(S1530-793X), 2005, 21(2): 234–238.

[13] Patricia P, Parlevliet, Harald E N. Measurement of (post-) curing strain development with fibre Bragg gratings [J]. Polymer Testing(S0142-9418), 2010, 29(3): 291–301.

卢少微, 高禹, 张海军, 王继杰. 树脂传递模塑成型注模过程的光纤光栅监测[J]. 光电工程, 2012, 39(10): 78. LU Shao-wei, GAO Yu, ZHANG Hai-jun, WANG Ji-jie. Monitoring the Injection Process of Resin Transfer Molding with Fiber Bragg Gratings[J]. Opto-Electronic Engineering, 2012, 39(10): 78.