摘要
利用碲镉汞(HgCdTe)体晶材料,采用HgCdTe 材料拼接技术、磨抛技术等成熟的探测器芯片制备工艺以及三级热电制冷技术,设计并研制出了热电制冷型13 元HgCdTe 中波红外光导探测器。在-50℃时,峰值电压响应率可达2.7×104 V/W,峰值探测率达到2.3×1010 cm·Hz1/2·W-1,响应波段在3.0~4.6 μm 之间,峰值响应波长为4.2 μm。
Abstract
By using bulk HgCdTe crystal materials, the detector chip preparation process including HgCdTe material splicing and polishing technology, and three-stage thermoelectric refrigeration technology, a thermoelectric-refrigerator-type 13-pixel HgCdTe photoconductive mid-wavelength infrared detector is designed and manufactured. At a temperature of -50℃, the peak voltage response can reach 2.7×104 V/W, the peak detection reaches 2.3×1010 cm·Hz1/2·W-1, and the response band is in the range of 3.0-4.6 μm with a peak response wavelength of 4.2 μm.
参考文献

[1] Lutz H, Breiter R, Figgemeier H, et al. Improved high operating temperature MCT MWIR modules[C]//Proc. of SPIE, 2014, 9070: 90701D.

[2] David B L, Philippe T, Frédéric P, et al. New IR detectors with small pixel pitch and high operating Temperature[C]//Proc. of SPIE, 2010, 7854: 78540M.

[3] Michel V, Laurent R, Fabien C, et al. HOT infrared detectors using MCT technology[C]//Proc. of SPIE, 2011, 8012: 80122W.

[4] 叶柏松,刘飞,袁永刚,等.HgCdTe轴温探测器噪声的温度特性研究[J].传感器与微系统,2013,32(12):49-54.

    YE Baisong, LIU Fei, YUAN Yonggang, et al. Study on temperature characteristic of noise of HgCdTe shaft temperature detector[J]. Transducer and Microsystem Technologies, 2013, 32(12): 49-54.

[5] 罗来邦,王述琪,张力,等.热电制冷中波红外探测器在末敏弹上的应用[J].探测与控制学报,2010,32(1):35-38.

    LUO Laibang, WANG Shuqi, ZHANG Li, et al. Application of TE-cooled medium wave IR detector to smart ammunition[J]. Journal of Detection & Control, 2010, 32(1): 35-38.

[6] 吴宗凡,柳美琳,张绍举,等.红外与微光技术[M].北京:国防工业出版社,1998.

    WU Zongfan, LIU Meilin, ZHANG Shaoju, et al. Infrared and Micro Light Technology[M]. Beijing: National Defense Industry Press, 1998.

[7] 邢素霞.非制冷红外热成像系统研究[D].南京:南京理工大学,2005.

    XING Suxia. Research on Uncooled Infrared Thermal Imaging System[D]. Nanjing: Nanjing University of Science and Technology, 2005.

[8] 冯国斌,张检民,杨鹏翎,等.室温中红外HgCdTe光导探测器响应率的温度特性[J].光子学报,2013,42(7):787-791.

    FENG Guobin, ZHANG Jianmin, YANG Pengling, et al. Responsivity variation with temperature of uncooled mid-infrared HgCdTe photoconductive detector[J]. Acta Photonica Sinica, 2013, 42(7): 787-791.

苏玉辉, 冯江敏, 赵维艳, 龚晓霞, 马启, 邓功荣, 余连杰. 热电制冷HgCdTe 中波红外探测器的研制[J]. 红外技术, 2017, 39(8): 700. SU Yuhui, FENG Jiangmin, ZHAO Weiyan, GONG Xiaoxia, MA Qi, DENG Gongrong, YU Lianjie. Thermoelectric-Cooled HgCdTe MWIR Detectors[J]. Infrared Technology, 2017, 39(8): 700.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!